ReviewMicrosystems & nanoengineering2024
On-chip dielectrophoretic single-cell manipulation.
Review in Microsystems & nanoengineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- Unraveling the dielectric heterogeneity response of cell lines under electroporation: a microfluidic single-cell on-chip system.Microsystems & nanoengineering · 2026Article
- Electric-Field-Assisted Enrichment and Electrochemical Detection of Gram-Positive Bacteria Using an FEM-Guided Interdigitated Electrode Biosensor.Biosensors · 2026Article
- Integrating Low-Voltage Microfluidics With On-Chip Electrospray Ionization for Miniaturized Protein Analysis.Small methods · 2026Review
- Structural, Compositional, and Dielectric State Profiling in Label-Free Single-Cell Monitoring.Small methods · 2026Review
- Capillary microfluidics aided single-cell manipulation for optical detection of bacterial pathogens.Biophysical reviews · 2026Review
- On-Demand Droplet Routing and Splitting Using Independently Addressable Interdigitated Electrodes.Micromachines · 2026Article
- Strategies to control cellular spatial organization in microphysiological systems.Microsystems & nanoengineering · 2026Review
- DEP-track: a motion-aware framework for large-scale cell tracking and crossover frequency estimation in dielectrophoresis.Frontiers in bioinformatics · 2026Article
- Article
- A 3D-printed microdevice for dielectrophoretic torque-driven rotation of dielectric microspheres to support development of manipulation systems for zebrafish eggs.Journal of micromechanics and microengineering : structures, devices, and systems · 2025Article
- Tunable Electrokinetic Motion of Charged Nanoparticles in an Aqueous Solution Using Interdigitated Microelectrodes.Nanomaterials (Basel, Switzerland) · 2025Article
- All-in-One Method for Iterative Single-Cell Dielectrophoretic and Optical Characterization: Advancing the OpenDEP Platform.ACS omega · 2025Article
- Electronic selection of viable Legionella cells by a video-based, quantifiable dielectrophoresis approach.Biomedical microdevices · 2025Article
- Isolation Techniques of Micro/Nano-Scaled Species for Biomedical Applications.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Bioanalysis at a single-cell level has yielded unparalleled insight into the heterogeneity of complex biological samples. Combined with Lab-on-a-Chip concepts, various simultaneous and high-frequency techniques and microfluidic platforms have led to the development of high-throughput platforms for single-cell analysis. Dielectrophoresis (DEP), an electrical approach based on the dielectric property of target cells, makes it possible to efficiently manipulate individual cells without labeling. This review focusses on the engineering designs of recent advanced microfluidic designs that utilize DEP techniques for multiple single-cell analyses. On-chip DEP is primarily effectuated by the induced dipole of dielectric particles, (i.e., cells) in a non-uniform electric field. In addition to simply capturing and releasing particles, DEP can also aid in more complex manipulations, such as rotation and moving along arbitrary predefined routes for numerous applications. Correspondingly, DEP electrodes can be designed with different patterns to achieve different geometric boundaries of the electric fields. Since many single-cell analyses require isolation and compartmentalization of individual cells, specific microstructures can also be incorporated into DEP devices. This article discusses common electrical and physical designs of single-cell DEP microfluidic devices as well as different categories of electrodes and microstructures. In addition, an up-to-date summary of achievements and challenges in current designs, together with prospects for future design direction, is provided.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.