The Impact of Dose Calibration Point Differences Between the Treatment Plan and Patient-specific Quality Assurance in Passive Scattering Proton Beam Therapy.

Yutaro Mori, Tomonori Isobe, Hideyuki Takei, Satoshi Kamizawa, Tetsuya Tomita, Daisuke Kobayashi, Hideyuki Sakurai, Takeji Sakae

Abstract read
In one paragraph

Article in In vivo (Athens, Greece). The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yutaro MoriInstitute of Medicine, University of Tsukuba, Tsukuba, Japan.
Tomonori IsobeInstitute of Medicine, University of Tsukuba, Tsukuba, Japan; tiso@md.tsukuba.ac.jp.
Hideyuki TakeiQuantum Life and Medical Science Directorate, National Institute for Quantum Science and Technology, Inage, Japan.
Satoshi KamizawaProton Medical Research Center, University of Tsukuba Hospital, Tsukuba, Japan.
Tetsuya TomitaDepartment of Radiology, University of Tsukuba Hospital, Tsukuba, Japan.
Daisuke KobayashiDepartment of Radiology, University of Tsukuba Hospital, Tsukuba, Japan.
Hideyuki SakuraiInstitute of Medicine, University of Tsukuba, Tsukuba, Japan.
Takeji SakaeInstitute of Medicine, University of Tsukuba, Tsukuba, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND/

aimPassive scattering proton beam therapy (PSPT) is performed by taking actual measurements of all pre-designated fields in a treatment plan followed by appropriate adjustments to the prescribed dose. For this reason, it is necessary to ensure precision management of the measurements (patient-specific calibration) in the administration of a planned dose. Therefore, this study investigated the impact on dose distribution in treatment planning when the patient calibration point differs from the normalized point in a treatment plan. PATIENTS AND

methodsA total of 16 cases were selected, where the patient calibration point and normalized point did not match, and the normalized point used in the treatment plan was changed to the patient calibration point using a treatment planning system (VQA ver. 2.01, HITACHI). At this point, the displacement of the relative dose at the isocenter was estimated as an error owing to the difference compared to the patient calibration point.

resultsOverall, the error was within the range of ±1.5%, with the exception of orbit cases. Calibrated points also tended to be lower than the normalized points in the treatment plan. In terms of treatment sites, a greater deviation was observed for head cases. Cases with a large deviation in sites other than the head were attributed to poor flatness within the radiation field owing to a narrower opening of the patient collimator.

conclusionDose measurement errors in PSPT due to differing calibration points were generally within ±1.5%, with higher deviations observed in head treatments because of complex structures and narrow collimator openings. A γ analysis for significant deviations showed a 98.7% passing rate, suggesting limited overall impact. It is important to select stable calibration points in dosimetry to ensure high precision in dose administration, particularly in complex treatment areas.

Indexed as

Proton TherapyQuality Assurance, Health CareRadiotherapy DosageRadiotherapy Planning, Computer-AssistedCalibrationHumansNeoplasmsRadiometrydosimetrypassive scatteringpatient-specific quality assuranceProton beam therapy

Identifiers

PMID39187337
PMCPMC11363771

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.