Evidence map›Paper›PMID 39183895›Full record

ArticleIEEE robotics and automation letters2020

Design, Modeling, and Control of a Coaxially Aligned Steerable (COAST) Guidewire Robot.

Seokhwan Jeong, Yash Chitalia, Jaydev P Desai

Abstract read
In one paragraph

Article in IEEE robotics and automation letters, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

25 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Self-Steering Catheters for Neuroendovascular Interventions.IEEE transactions on medical robotics and bionics · 2024
    Article
  11. Article
  12. Article
  13. Article
  14. Towards a Robotically Steerable Laser Ablation Probe.... International Symposium on Medical Robotics. International Symposium on Medical Robotics · 2024
    Article
  15. Article
  16. A Model to Predict Deflection of an Active Tendon-Driven Notched Needle Inside Soft Tissue.Journal of engineering and science in medical diagnostics and therapy · 2024
    Article
  17. A Telescopic Tendon-Driven Needle Robot for Minimally Invasive Neurosurgery.Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems · 2023
    Article
  18. Article
  19. Article
  20. Real-time Pose Tracking for a Continuum Guidewire Robot under Fluoroscopic Imaging.IEEE transactions on medical robotics and bionics · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Seokhwan JeongMedical Robotics and Automation (RoboMed) Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA.
Yash ChitaliaMedical Robotics and Automation (RoboMed) Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA.
Jaydev P DesaiMedical Robotics and Automation (RoboMed) Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA.

Funding

Ultrasound-guided, Robotically Steerable Guidewire for Endovascular InterventionsR01HL144714 · NHLBI · GEORGIA INSTITUTE OF TECHNOLOGY · PI DESAI, JAYDEV P. · 2019 to 2022
$2.8M
NHLBI NIH HHS R01 HL144714
6 · The paper itself

Abstract

Manual navigation of a guidewire is the first step in endovascular interventions. However, this procedure is time consuming with uncertain results due to tortuous vascular anatomy. This paper introduces the design of a novel COaxially Aligned STeerable (COAST) guidewire robot that is 0.40 mm in diameter demonstrating variable curvature and independently controlled bending length of the distal end. The COAST design involves three coaxially aligned tubes with a single tendon running centrally through the length of robot. The outer tubes are made from micromachined nitinol allowing for tendon-driven bending of the robot at various segments of the robot, thereby enabling variable bending curvatures, while an inner stainless steel tube controls the bending length of the robot. By varying relative positions of the tubes and the tendon by insertion and retraction in the entire assembly, various joint lengths and curvatures can be achieved, which enables a follow-the-leader motion. We model the kinematics, statics, as well as the coupling within tubes of the COAST robot and develop a simple controller to control the distal tip of the robot. Finally, we experimentally demonstrate the ability of COAST guidewire to accurately navigate through phantom anatomical bifurcations and tortuous anatomy.

Indexed as

Mechanism DesignMedical Robots and SystemsSteerable Catheters/NeedlesSurgical Robotics

Identifiers

PMID39183895
PMCPMC11343510

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.