ArticleEuropean radiology2025
Survey of CT radiation doses and iodinated contrast medium administration: an international multicentric study.
Article in European radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Vendor-agnostic versus vendor-specific boost methods in low-concentration contrast-enhanced computed tomography of the abdomen.Quantitative imaging in medicine and surgery · 2026Article
- Radiation dose has no significant impact on CT-based bone mineral density measurements in a large-animal model.Scientific reports · 2026Article
- Preliminary Evaluation of the Effect of Body Weight on Contrast Enhancement in Coronary CT Angiography: A Fixed Iodine-Dose Protocol.Diagnostics (Basel, Switzerland) · 2026Article
- Innovation and Optimization of Contrast Media Administration in Computed Tomography.Korean journal of radiology · 2025Article
- Global research hotspots and trends of iodinated contrast agents in medical imaging: a bibliometric and visualization analysis.Frontiers in medicine · 2024Article
- Comparison Between Weight-Based Variable-Voltage and Fixed Volume-Voltage Protocols in Cancer Surveillance Computed Tomography.Journal of computer assisted tomographyArticle
Corrections and comments
- Commented on by
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo assess the relationship between intravenous iodinated contrast media (ICM) administration usage and radiation doses for contrast-enhanced (CE) CT of head, chest, and abdomen-pelvis (AP) in international, multicenter settings.
methodsOur international (n = 16 countries), multicenter (n = 43 sites), and cross-sectional (ConRad) study had two parts. Part 1: Redcap survey with questions on information related to CT and ICM manufacturer/brand and respective protocols. Part 2: Information on 3,258 patients (18-96 years; M:F 1654:1604) who underwent CECT for a routine head (n = 456), chest (n = 528), AP (n = 599), head CT angiography (n = 539), pulmonary embolism (n = 599), and liver CT examinations (n = 537) at 43 sites across five continents. The following information was recorded: hospital name, patient age, gender, body mass index [BMI], clinical indications, scan parameters (number of scan phases, kV), IV-contrast information (concentration, volume, flow rate, and delay), and dose indices (CTDIvol and DLP).
resultsMost routine chest (58.4%) and AP (68.7%) CECT exams were performed with 2-4 scan phases with fixed scan delay (chest 71.4%; AP 79.8%, liver CECT 50.7%) following ICM administration. Most sites did not change kV across different patients and scan phases; most CECT protocols were performed at 120-140 kV (83%, 1979/2685). There were no significant differences between radiation doses for non-contrast (CTDIvol 24 [16-30] mGy; DLP 633 [414-702] mGy·cm) and post-contrast phases (22 [19-27] mGy; 648 [392-694] mGy·cm) (p = 0.142). Sites that used bolus tracking for chest and AP CECT had lower CTDIvol than sites with fixed scan delays (p < 0.001). There was no correlation between BMI and CTDIvol (r
conclusionOur study demonstrates up to ten-fold variability in ICM injection protocols and radiation doses across different CT protocols. The study emphasizes the need for optimizing CT scanning and contrast protocols to reduce unnecessary contrast and radiation exposure to patients. CLINICAL RELEVANCE STATEMENT: The wide variability and lack of standardization of ICM media and radiation doses in CT protocols suggest the need for education and optimization of contrast usage and scan factors for optimizing image quality in CECT. KEY POINTS: There is a lack of patient-centric CT protocol optimization taking into consideration mainly patients' size. There is a lack of correlation between ICM volume and CT radiation dose across CT protocol. A ten-fold variation in iodine-load for the same CT protocol in sites suggests a lack of standardization.
Indexed as
Identifiers
39181948What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.