ReviewBDJ open2024
Does strontium coated titanium implants enhance the osseointegration in animal models under osteoporotic condition? A systematic review and meta-analysis.
Review in BDJ open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Clinical and radiographic evaluation of immediate versus delayed loading of dental implants at anterior maxilla: a randomized controlled trial.BMC oral health · 2026Trial
- Innovations in Implant Osseointegration: Biomaterials, Surface Engineering, and Translational Strategies.Journal of biomedical materials research. Part A · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe aim of this study was to systematically review the literature to address the effect of strontium modified titanium implants on the osseointegration in the presence of osteoporotic conditions through animal models. MATERIALS AND
methodsThe databases (PubMed, Scopus, Web of Science, and EBSCO) were searched electronically, and manual searches were performed till December 2022 to identify preclinical studies on the osseointegration of strontium coated titanium implants in animals with induced osteoporotic conditions. The primary outcomes were the bone-implant contact percentage (BIC%), bone area (BA) from the histomorphometric analysis, and the osseointegration parameters from biomechanical tests; the secondary outcomes were the osseointegration parameters from the micro computed tomography.
resultsNineteen articles were included for the quantitative analysis on basis of the inclusion criteria. The results revealed that Sr-modified implants showed a significant 19.05% increase in BIC, and 15.01% increase in BA. The results of biomechanical tests indicated a significant effect in favor of Sr-coated implants. Furthermore, Results of the secondary outcomes supported the significant advantages of Sr-coated implants over the un-coated implants. The overall, systematic analysis of implants osteointegration parameters proved a significant increase in favor of Sr-coated titanium implants (P < 0.01).
conclusionThe present results provide evidence that strontium-coated titanium implants enhanced the osseointegration in animal models under osteoporotic condition as this surface modification techniques have improved the mechanical and biological properties of the titanium implants.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.