ArticleJournal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie2026
Three-dimensional analysis of posttreatment tooth movements despite bonded retainers: part II-lower jaw.
Article in Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Effect of Bonding Height on Force-Moment Generation in Orthodontic Fixed Lingual Retainers: An In Vitro Study.Clinical and experimental dental research · 2026Article
- Three-dimensional stability during orthodontic retention: A comparative analysis of conventional, CAD/CAM-fabricated, and robotically bent fixed retainers versus removable appliances.Clinical oral investigations · 2026Article
- Digital three-dimensional planning combined with 3D-printed patient-specific guide-assisted step-cut osteotomy for correction of old cubitus varus deformity: a case report.Frontiers in surgery · 2026Article
- In Vitro Investigation Using a New Biomechanical Force-Torque Analysis System: Comparison of Conventional and CAD/CAM-Fixed Orthodontic Retainers.Materials (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeComplications of bonded lingual retainers in terms of unexpected tooth movements have been reported with increasing frequency during the last decade, but the vast majority of the literature comprises case reports. The purpose of the present retrospective case-control study was to analyze the amount and direction of unwanted tooth movements despite lower bonded retainers, to analyze possible predisposing pretreatment- and treatment-related factors, and to seek for movement thresholds which could enhance the rapid and objective identification of critical cases.
methodsPlaster casts of 1026 patients who completed orthodontic treatment and a subsequent retention phase of 2 years were screened for unintentional tooth movements. The study group comprised 39 patients with tooth movements in the lower jaw, while 39 randomly selected patients without visible tooth movements served as the control group. For all patients, plaster casts after debonding of multibracket appliances (T1) and after supervised retention (T2) were digitized, and a three-dimensional (3D) digital superimposition based on the best fit of premolars and molars was undertaken. Thereafter, translational as well as rotational movements were measured in all three planes of space. Pretreatment- and treatment-related factors of the study and control groups were compared. A severity classification based on rotational movement thresholds was applied to seek a critical amount of translational movements.
resultsThe mean translational movements ranged between 0 and 0.4 mm and the average rotational movements between 0 and 1.6°. Large individual movements up to 1.9 mm translation and 16° rotation were seen. A twist-effect with opposite movements of the canines along the Y‑axis could be confirmed. Compared to the control group, patients of the study group had a smaller intercanine distance at all timepoints. In addition, study group patients presented a slightly larger intercanine expansion during treatment and were more often affected by retainer bonding site detachments. Applying the severity classification based on rotational thresholds, translational movements of 0.5-1.0 mm along the X‑ and Y‑axis could serve as a critical threshold. It can be assumed that extrusive translational movements along the Z‑axis seem to be of specific nature and perhaps do not reflect a retainer complication in terms of unwanted tooth movements.
conclusionsPatients with a larger intercanine distance after active treatment and those with more frequent retainer bonding site detachments could be at higher risk for unwanted tooth movements during fixed retention. Sagittal and transverse movements of 0.5-1.0 mm should sensitize the practitioner for further measures.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.