Evidence map›Paper›PMID 39176298›Full record

ArticleCurrent urology2024

Does a large prostate size, small lesion volume, or long needle distance from the probe to the lesion reduce magnetic resonance imaging-targeted cancer detection?

Mark D Bevill, Justin N Drobish, Kevin J Flynn, Maheen Rajput, Catherine Metz, Chad R Tracy, Paul T Gellhaus

Abstract read
In one paragraph

Article in Current urology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mark D BevillDepartment of Urology, University of Iowa Carver College of Medicine, Iowa City, IA, USA.
Justin N DrobishDepartment of Urology, University of Iowa Carver College of Medicine, Iowa City, IA, USA.
Kevin J FlynnDepartment of Urology, University of Iowa Carver College of Medicine, Iowa City, IA, USA.
Maheen RajputDepartment of Radiology, University of Iowa Carver College of Medicine, Iowa City, IA, USA.
Catherine MetzDepartment of Radiology, University of Iowa Carver College of Medicine, Iowa City, IA, USA.
Chad R TracyDepartment of Urology, University of Iowa Carver College of Medicine, Iowa City, IA, USA.
Paul T GellhausDepartment of Urology, University of Iowa Carver College of Medicine, Iowa City, IA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: We aimed to evaluate whether large prostate size, small lesion volume, or long lesion distance from the ultrasound probe tip would decrease cancer detection in transrectal magnetic resonance imaging (MRI)-targeted biopsies. Materials and methods: Patients who underwent MRI-targeted biopsy at our institution between May 2017 and August 2019 were enrolled in a prospective database. Three to 5 cores were obtained from ≥2 prostate imaging reporting and data system v2 lesions. A multivariable model was created that included needle distance to the lesion, prostate specific antigen, prostate imaging reporting and data system, lesion volume, and prostate volume. Results: A total of 377 patients with 533 lesions underwent a biopsy during the study period. A total of 233 (44%) lesions were positive for prostate cancer, and 173 (32%) lesions had clinically significant prostate cancer. The mean needle distance to the lesion was 11.7 mm (interquartile range, 7.6-15.5 mm). The likelihood of obtaining a positive core on biopsy decreased as the distance from the ultrasound probe increased for all prostate cancers and clinically significant prostate cancer ( Conclusions: Our data showed that transrectal MRI-targeted biopsy cancer detection modestly decreased the lesion from the ultrasound probe and with a large prostate volume but could not prove that lesion volume was a significant predictor of the amount of cancer detected.

Indexed as

BiopsyMagnetic resonance imagingProstate cancer

Identifiers

PMID39176298
PMCPMC11337985

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials