Evidence map›Paper›PMID 39175612›Full record

ArticleFrontiers in physiology2024

Automatic cardiothoracic ratio calculation based on lung fields abstracted from chest X-ray images without heart segmentation.

Yingjian Yang, Jie Zheng, Peng Guo, Tianqi Wu, Qi Gao, Yingwei Guo, Ziran Chen, Chengcheng Liu, Zhanglei Ouyang, Huai Chen and 1 more

Abstract read
In one paragraph

Article in Frontiers in physiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Yingjian Yang *Department of Radiological Research and Development, Shenzhen Lanmage Medical Technology Co., Ltd., Shenzhen, Guangdong, China.
Jie Zheng *Department of Radiological Research and Development, Shenzhen Lanmage Medical Technology Co., Ltd., Shenzhen, Guangdong, China.
Peng Guo *Department of Radiological Research and Development, Shenzhen Lanmage Medical Technology Co., Ltd., Shenzhen, Guangdong, China.
Tianqi WuDepartment of Radiological Research and Development, Shenzhen Lanmage Medical Technology Co., Ltd., Shenzhen, Guangdong, China.
Qi GaoNeusoft Medical System Co., Ltd., Shenyang, Liaoning, China.
Yingwei GuoSchool of Electrical and Information Engineering, Northeast Petroleum University, Daqing, China.
Ziran ChenCollege of Medicine and Biological Information Engineering, Northeastern University, Shenyang, China.
Chengcheng LiuSchool of Life and Health Management, Shenyang City University, Shenyang, China.
Zhanglei OuyangDepartment of Radiological Research and Development, Shenzhen Lanmage Medical Technology Co., Ltd., Shenzhen, Guangdong, China.
Huai ChenDepartment of Radiology, The Second Affiliated Hospital of Guangzhou Medical University, Guangzhou China.
Yan KangCollege of Medicine and Biological Information Engineering, Northeastern University, Shenyang, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: The cardiothoracic ratio (CTR) based on postero-anterior chest X-rays (P-A CXR) images is one of the most commonly used cardiac measurement methods and an indicator for initially evaluating cardiac diseases. However, the hearts are not readily observable on P-A CXR images compared to the lung fields. Therefore, radiologists often manually determine the CTR's right and left heart border points of the adjacent left and right lung fields to the heart based on P-A CXR images. Meanwhile, manual CTR measurement based on the P-A CXR image requires experienced radiologists and is time-consuming and laborious. Methods: Based on the above, this article proposes a novel, fully automatic CTR calculation method based on lung fields abstracted from the P-A CXR images using convolutional neural networks (CNNs), overcoming the limitations to heart segmentation and avoiding errors in heart segmentation. First, the lung field mask images are abstracted from the P-A CXR images based on the pre-trained CNNs. Second, a novel localization method of the heart's right and left border points is proposed based on the two-dimensional projection morphology of the lung field mask images using graphics. Results: The results show that the mean distance errors at the Discussion: Our proposed model achieves the equivalent performance of CTR calculation as the previous CardioNet model, overcomes heart segmentation, and takes less time. Therefore, our proposed method is practical and feasible and may become an effective tool for initially evaluating cardiac diseases.

Indexed as

cardiothoracic ratiochest X-ray imagesconvolutional neural networkedge detectiongraphicslung field segmentation

Identifiers

PMID39175612
PMCPMC11338915

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.