Evidence map›Paper›PMID 39175021›Full record

ArticleJournal of orthopaedic surgery and research2024

Biomechanical comparison of femoral neck anti-rotation and support system versus femoral neck system for unstable pauwels III femoral neck fractures.

Taiyou Wang, Guangjian Wang, Fukang Zhu, Bo Qiao

Abstract readComparative Study
In one paragraph

Article in Journal of orthopaedic surgery and research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Taiyou Wang *Department of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, 1 Youyi Rd, Chongqing, 400010, P. R. China.
Guangjian Wang *Department of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, 1 Youyi Rd, Chongqing, 400010, P. R. China.
Fukang ZhuDepartment of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, 1 Youyi Rd, Chongqing, 400010, P. R. China.
Bo QiaoDepartment of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, 1 Youyi Rd, Chongqing, 400010, P. R. China. qiaobo1985@163.com.

Funding

Chongqing Municipal Science and Technology Bureau cstc2020jscx-sbqwX0010
6 · The paper itself

Abstract

backgroundThe optimal treatment method for managing unstable Pauwels III femoral neck fractures remains undetermined. The aim of this study was to compare the biomechanical properties of two types of Femoral Neck Anti-rotation and Support System (FNAS) and a Femoral Neck System (FNS) in unstable Pauwels III femoral neck fractures.

methodsEighteen synthetic femoral models were implanted with one of three fixation devices: FNS, FNAS I, or FNAS II. An unstable Pauwels III (OTA/AO 31-B2.3) femoral neck fracture was simulated using a custom-made needle and osteotomy guide. Torsion and axial compression loading tests were conducted, and the torque, torsion angle, load to failure, displacement, and stiffness values were recorded.

resultsFNAS II exhibited significantly higher torsional stiffness (0.67 ± 0.10 Nm/°) compared to FNAS I (0.52 ± 0.07 Nm/°, P = 0.01) and FNS (0.54 ± 0.07 Nm/°, P = 0.005). FNS demonstrated significantly greater mean axial stiffness (239.24 ± 11.38 N/mm) than both FNAS I (179.33 ± 31.11 N/mm, P = 0.005) and FNAS II (190.07 ± 34.11 N/mm, P = 0.022). FNAS I (302.37 ± 33.88 N/mm, P = 0.001) and FNAS II (319.59 ± 50.10 N/mm, P < 0.001) showed significantly higher initial axial stiffness compared to FNS (197.08 ± 33.68 N/mm). Both FNAS I and II improved resistance to deforming forces at a load level before approximately 1000 N, which is sufficient to withstand the load from most daily life activities. No significant differences were observed in compression failure load among the groups. The failure patterns at the point of failure included the pull-out of the distal locking screw and reverse oblique intertrochanteric femur fracture for FNS, while for FNAS I and II, the failures were characterized by a cleft on the calcar femorale and a decrease in the load-displacement curve.

conclusionsIn unstable Pauwels III femoral neck fractures, the FNAS II enhances stability and is easier to manage for reoperation. The results of the current study support the potential of FNAS II as an alternative option for treating unstable Pauwels III femoral neck fractures in young individuals.

Indexed as

Femoral Neck FracturesFracture Fixation, InternalBiomechanical PhenomenaFemur NeckHumansRotationBiomechanicsFemoral Neck anti-rotation and support systemFemoral neck fracturesFemoral Neck System

Identifiers

PMID39175021
PMCPMC11340060

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.