Evidence map›Paper›PMID 39174518›Full record

ArticleNature communications2024

An integrated and flexible ultrasonic device for continuous bladder volume monitoring.

Alp Timucin Toymus, Umut Can Yener, Emine Bardakci, Özgür Deniz Temel, Ersin Koseoglu, Dincay Akcoren, Burak Eminoglu, Mohsin Ali, Rasim Kilic, Tufan Tarcan and 1 more

Abstract read
In one paragraph

Article in Nature communications, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Mechanomedicine.Nature reviews bioengineering · 2026
    Article
  8. Article
  9. Review
  10. Article
  11. Review
  12. Article
  13. Review
  14. Article
  15. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

11 authors.

Alp Timucin Toymus *Department of Mechanical Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey.
Umut Can Yener *Department of Mechanical Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey.
Emine Bardakci *Department of Electrical and Electronics Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey.
Özgür Deniz TemelDepartment of Electrical and Electronics Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey.
Ersin KoseogluDepartment of Urology, School of Medicine, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey.ORCID 0000-0002-5189-0600
Dincay AkcorenAnalog Devices, Inc. (ADI), One Analog Way, Wilmington, MA, 01887, USA.
Burak EminogluDepartment of Electrical Engineering and Computer Sciences, University of California, Berkeley, Berkeley, CA, USA.
Mohsin AliDepartment of Biomedical Sciences and Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey.
Rasim KilicDepartment of Biomedical Sciences and Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey.
Tufan TarcanDepartment of Urology, School of Medicine, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey.
Levent BekerDepartment of Mechanical Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey. lbeker@ku.edu.tr.ORCID 0000-0002-9777-6619

Funding

EC | EU Framework Programme for Research and Innovation H2020 | H2020 Priority Excellent Science | H2020 European Research Council (H2020 Excellent Science - European Research Council) 101043119
6 · The paper itself

Abstract

Bladder volume measurement is critical for early detection and management of lower urinary tract dysfunctions. Current gold standard is invasive, and alternative technologies either require trained personnel or do not offer medical grade information. Here, we report an integrated wearable ultrasonic bladder volume monitoring device for accurate and autonomous continuous monitoring of the bladder volume. The device incorporates flexible and air-backed ultrasonic transducers and miniaturized control electronics with wireless data transmission capability. We demonstrate the real-life application of the device on healthy volunteers with various bladder shapes and sizes with high accuracy. Apart from the lower urinary tract dysfunctions, the proposed technology could also be adapted for various wearable ultrasonic applications.

Indexed as

UltrasonographyUrinary BladderAdultEquipment DesignFemaleHealthy VolunteersHumansMaleMonitoring, PhysiologicOrgan SizeTransducersWearable Electronic DevicesWireless Technology

Identifiers

PMID39174518
PMCPMC11341558

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.