Evidence map›Paper›PMID 39173059›Full record

ArticlePloS one2024

The relationship between mechanical power normalized to dynamic lung compliance and weaning outcomes in mechanically ventilated patients.

Yao Yan, Zhiqiang Du, Haoran Chen, Suxia Liu, Xiaobing Chen, Xiaomin Li, Yongpeng Xie

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Observational
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yao YanDepartment of Critical Care Medicine, The Second People's Hospital of Lianyungang City, Affiliated to Kangda College of Nanjing Medical University, Lianyungang, Jiangsu, China.ORCID 0000-0001-8000-6952
Zhiqiang DuDepartment of Critical Care Medicine, The Second People's Hospital of Lianyungang City, Affiliated to Kangda College of Nanjing Medical University, Lianyungang, Jiangsu, China.
Haoran ChenKangda College of Nanjing Medical University, Lianyungang, Jiangsu, China.ORCID 0000-0002-8698-8712
Suxia LiuDepartment of Critical Care Medicine, Lianyungang Clinical College of Nanjing Medical University, The First People's Hospital of Lianyungang City, Lianyungang, Jiangsu, China.
Xiaobing ChenDepartment of Emergency Medicine, Lianyungang Clinical College of Nanjing Medical University, The First People's Hospital of Lianyungang City, Lianyungang, Jiangsu, China.
Xiaomin LiDepartment of Emergency Medicine, Lianyungang Clinical College of Nanjing Medical University, The First People's Hospital of Lianyungang City, Lianyungang, Jiangsu, China.
Yongpeng XieDepartment of Emergency Medicine, Lianyungang Clinical College of Nanjing Medical University, The First People's Hospital of Lianyungang City, Lianyungang, Jiangsu, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundProlonged mechanical ventilation is associated with an increased risk of mortality in these patients. However, there exists a significant clinical need for novel indicators that can complement traditional weaning evaluation methods and effectively guide ventilator weaning.

objectivesTo investigate the specific relationship between mechanical power normalized to dynamic lung compliance (Cdyn-MP) and weaning outcomes in patients on mechanical ventilation for more than 24 hours, as well as those who underwent a T-tube weaning strategy.

methodsA retrospective cohort study was conducted using the Medical Information Mart for Intensive Care-IV v1.0 database (MIMIC-IV v1.0). Patients who received invasive mechanical ventilation for more than 24 hours and underwent a T-tube ventilation strategy for weaning were enrolled. Patients were divided into two groups based on their weaning outcome: weaning success and failure. Ventilation parameter data were collected every 4 hours during the first 24 hours before the first spontaneous breathing trial (SBT).

resultsOf all the 3,695 patients, 1,421 (38.5%) experienced weaning failure. Univariate logistic regression analysis revealed that the risk of weaning failure increased as the Cdyn-MP level rose (OR 1.34, 95% CI 1.31-1.38, P<0.001). After adjusting for age, body mass index, disease severity, and pre-weaning disease status, patients with high Cdyn-MP quartiles in the 4 hours prior to the SBT had a significantly greater risk of weaning failure than those with low Cdyn-MP quartiles (odds ratio 10.37, 95% CI 7.56-14.24). These findings were robust and consistent in both subgroup and sensitivity analyses.

conclusionThe increased Cdyn-MP before SBT was independently associated with a higher risk of weaning failure in mechanically ventilated patients. Cdyn-MP has the potential to be a useful indicator for guiding the need for ventilator weaning and complementing traditional weaning evaluation methods.

Indexed as

Respiration, ArtificialVentilator WeaningAgedFemaleHumansLung ComplianceMaleMiddle AgedRetrospective Studies

Identifiers

PMID39173059
PMCPMC11341020

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.