Evidence map›Paper›PMID 39172090›Full record

ArticleJournal of synchrotron radiation2024

Development of a flat jet delivery system for soft X-ray spectroscopy at MAX IV.

Tamires Gallo, Luigi Adriano, Michael Heymann, Agnieszka Wrona, Noelle Walsh, Gunnar Öhrwall, Flavia Callefo, Slawomir Skruszewicz, Mahesh Namboodiri, Ricardo Marinho and 2 more

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Tamires GalloLund University, Sweden.
Luigi AdrianoEuropean XFEL, Germany.
Michael HeymannUniversität Stuttgart, Germany.ORCID 0000-0002-9278-8207
Agnieszka WronaEuropean XFEL, Germany.ORCID 0009-0004-2174-003X
Noelle WalshMAX IV Laboratory, Sweden.
Gunnar ÖhrwallMAX IV Laboratory, Sweden.
Flavia CallefoBrazilian Synchrotron Light Laboratory, LNLS, Brazilian Center for Research in Energy and Materials (CPNEM), Brazil.ORCID 0000-0003-3707-8250
Slawomir SkruszewiczDeutsches Elektronen Synchrotron (DESY), Germany.
Mahesh NamboodiriDeutsches Elektronen Synchrotron (DESY), Germany.
Ricardo MarinhoInstitute of Physics, Brasilia University (UnB), 70.919-970 Brasília, Brazil.ORCID 0000-0001-5854-5589
Joachim SchulzEuropean XFEL, Germany.ORCID 0000-0002-9310-8832
Joana ValerioEuropean XFEL, Germany.ORCID 0000-0001-5931-0925

Funding

Carl Trygger Foundation CTS 20:502European Union's Horizon 2020 research and innovation program 101004728Formas 2019-02496foundations Aeryleanska resestipendiefonden and Bokelunds resestipendiefond RNv2021-0007Foundations Aeryleanska resestipendiefonden and Bokelunds resestipendiefond RNv2021-0007Swedish-Brazilian collaboration STINT-CAPES 88881.465527/2019-01Swedish Research Council 2018-07152The Swedish Governmental Agency for Innovation Systems 2018-04969
6 · The paper itself

Abstract

One of the most challenging aspects of X-ray research is the delivery of liquid sample flows into the soft X-ray beam. Currently, cylindrical microjets are the most commonly used sample injection systems for soft X-ray liquid spectroscopy. However, they suffer from several drawbacks, such as complicated geometry due to their curved surface. In this study, we propose a novel 3D-printed nozzle design by introducing microscopic flat sheet jets that provide micrometre-thick liquid sheets with high stability, intending to make this technology more widely available to users. Our research is a collaboration between the EuXFEL and MAX IV research facilities. This collaboration aims to develop and refine a 3D-printed flat sheet nozzle design and a versatile jetting platform that is compatible with multiple endstations and measurement techniques. Our flat sheet jet platform improves the stability of the jet and increases its surface area, enabling more precise scanning and differential measurements in X-ray absorption, scattering, and imaging applications. Here, we demonstrate the performance of this new arrangement for a flat sheet jet setup with X-ray photoelectron spectroscopy, photoelectron angular distribution, and soft X-ray absorption spectroscopy experiments performed at the photoemission endstation of the FlexPES beamline at MAX IV Laboratory in Lund, Sweden.

Indexed as

3D-printed flat jet nozzleliquid jet spectroscopyphotoelectron angular distributionphotoelectron spectroscopysoft X-ray absorption spectroscopy

Identifiers

PMID39172090
PMCPMC11371042

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.