SynthesisThe Cochrane database of systematic reviews2024
Surgical fixation methods for tibial plateau fractures.
Synthesis in The Cochrane database of systematic reviews, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Large language models for risk-of-bias assessment in randomised clinical trials-a comparative validation study.EBioMedicine · 2026Article
- Can FEM-based preoperative planning for complex tibial plateau fractures improve surgical skills? A cadaver study.Journal of orthopaedic surgery and research · 2026Article
- [Comparative study on effectiveness of double reverse traction reduction versus open reduction internal fixation in treating complex tibial plateau fractures].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2025Article
- Posterolateral tibia plateau fractures: pros and cons of different surgical approaches.EFORT open reviews · 2025Article
- Breaking the treatment dilemma of Schatzker IV fractures: finite element analysis validates hybrid single-plate with tension screw fixation for synergistic optimization of stability and minimally invasive outcomes.Frontiers in bioengineering and biotechnology · 2025Article
Corrections and comments
- Update of
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTibial plateau fractures, which are intra-articular injuries of the knee joint, are often difficult to treat and have a high complication rate, including early-onset osteoarthritis. The most common treatment for complex tibial plateau fractures is surgical fixation. Additionally, orthopaedic surgeons often use bone defect fillers to address bone defects caused by the injury. Currently, there is no consensus on the best method of fixation and on whether bone defect fillers are necessary.
objectivesTo assess the benefits and harms of different surgical interventions and bone defect fillers for treating tibial plateau fractures. SEARCH
methodsWe searched CENTRAL, MEDLINE, Embase, and trial registries up to March 2023. We also searched conference proceedings and the grey literature. SELECTION CRITERIA: We included randomised controlled trials (RCTs) and quasi-RCTs comparing surgical interventions for treating tibial plateau fractures and different types of filler for bone defects. DATA COLLECTION AND ANALYSIS: Two review authors independently screened search results, selected studies, extracted data, and assessed risk of bias. We calculated risk ratios (RRs) for dichotomous outcomes and mean differences (MDs) or standardised mean differences (SMDs) for continuous outcomes, with 95% confidence intervals (CIs). Our primary outcomes (and the specific measures we considered most relevant) were generic quality of life (general health score in the 36-item Short-Form Health Survey (SF-36)), patient-reported lower limb function (Hospital for Special Surgery (HSS) score), and adverse events (frequency of unplanned reoperation). We used GRADE to assess the certainty of evidence. MAIN
resultsWe included 15 trials in the review, with a total of 948 adult participants. Nine trials compared different types of fixation, and six trials evaluated different types of bone graft substitutes. All 15 trials were small and at high risk of bias. We considered most available evidence to be of very low certainty, meaning we have very little confidence in the results. Only limited pooling was possible. One trial compared circular fixation combined with insertion of percutaneous screws (hybrid fixation) versus standard open reduction and internal fixation (ORIF) in 82 people with open or closed Schatzker types V or VI tibial plateau fractures. At 24 months' follow-up, hybrid fixation compared with ORIF may have little or no effect on SF-36 general health score (MD 6 points higher, 95% CI 7.7 points lower to 19.7 points higher; 66 participants), patient-reported lower limb function according to the HSS score (MD 7 points higher, 95% CI 2.4 points lower to 16.4 points higher; 66 participants), or frequency of unplanned reoperation (RR 0.78, 95% CI 0.45 to 1.32; 83 fractures (82 participants)). However, the evidence for all three outcomes is very uncertain. Three trials (with 242 participants) compared single-plating ORIF versus double-plating ORIF. There may be little to know difference in patient-reported lower limb function (HSS score) at 24 months' follow-up in people who undergo single-plating ORIF compared with those who undergo double-plating ORIF (MD 0.2 points higher, 95% CI 2.12 points lower to 2.52 points higher; 1 study, 84 participants), but the evidence is very uncertain. There were no data for quality of life or unplanned reoperation at 24 months' follow-up. Six trials (including 368 participants) compared bone substitute versus autologous bone graft (autograft) for managing bone defects. No trials reported SF-36 general health score, HSS score, or frequency of unplanned reoperation at 24 months' follow-up. AUTHORS'
conclusionsThere is insufficient evidence to ascertain the best method of fixation or the best method of addressing bone defects during surgery in people with tibial plateau fractures. Further well-designed RCTs with larger sample sizes are warranted.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.