Evidence map›Paper›PMID 39171445›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2025

The Cobra sign: A marker for overestimation of tendon retraction in proximal semimembranosus tendon avulsion.

Nicolas Lefèvre, Mohamad K Moussa, Ahmad Chahal, Alain Meyer, Olivier Grimaud, Zeinab M Khalaf, Ali Alayane, Yoann Bohu, Alexandre Hardy

Abstract read
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. The Cobra sign: A marker for overestimation of tendon retraction in proximal semimembranosus tendon avulsion.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Nicolas LefèvreClinique du Sport, Paris, France.
Mohamad K MoussaDepartment of Orthopedic Surgery, Group Hospitalier Sélestat Obernai, Séléstat, Alsace, France.ORCID http://orcid.org/0000-0003-2611-3938
Ahmad ChahalDepartment of Radiology, Hôpital Saint Camille, Bry-sur-Marne, France.
Alain MeyerClinique du Sport, Paris, France.
Olivier GrimaudClinique du Sport, Paris, France.
Zeinab M KhalafClinique du Sport, Paris, France.
Ali AlayaneClinique du Sport, Paris, France.
Yoann BohuClinique du Sport, Paris, France.
Alexandre HardyClinique du Sport, Paris, France.

Funding

None
6 · The paper itself

Abstract

purposeTo introduce a new magnetic resonance imaging (MRI) sign, termed the Cobra sign, and identify its diagnostic metrics. The secondary aim was to demonstrate that this sign can be a source of false evaluation of tendon retraction in patients with proximal hamstring avulsion injury.

methodThis retrospective cohort study targeted patients surgically treated for proximal hamstring avulsion injury from January 2019 to June 2023. The MRI Cobra sign was defined as a wavy curved T2-hypointense band with the free end folding distally over itself, resembling a cobra head. The primary outcome measure was the characterization of the Cobra sign in patients with proximal hamstring avulsion injury. The secondary outcome was the association of this sign with tendon retraction. The study included 81 proximal hamstring avulsion injury patients (mean age of 45.7, SD = 13.9), with 41 (50.6%) complete avulsions, 33 semimembranosus, and 7 conjoint tendons.

resultsThe MRI Cobra sign was found in 25 patients (17 semimembranosus and 8 complete). It was confirmed surgically only in semimembranosus cases. It demonstrated 51.5% sensitivity and 83.3% specificity for isolated semimembranosus avulsions, with a significant positive likelihood ratio of 3.0. MRI retraction was 10.05 cm (±3.0), reducing to 7.9 cm (±2.5) on surgical measurement (mean difference = 2.0 cm, p < 0.001). The regression analysis confirmed MRI retraction's influence on the Cobra sign, with a 1.4 odds increase per unit (p < 0.001). In linear regression analysis, each unit increase in MRI retraction corresponded to a 79% increase in surgical retraction (coefficient 0.7, t = 11.1, p < 0.001).

conclusionThe Cobra sign demonstrated acceptable diagnostic accuracy for isolated semimembranosus avulsion, with a high specificity of 83.3%, a low sensitivity of 51.5%, and a positive likelihood ratio of 3.0. The presence of the Cobra sign indicates an overestimated MRI retraction by approximately 21%. LEVEL OF EVIDENCE: Level III.

Indexed as

Hamstring TendonsMagnetic Resonance ImagingTendon InjuriesAdultFemaleHumansMaleMiddle AgedRetrospective StudiesSensitivity and Specificityhamstring avulsionMRI retractionMRI signsemimembranosussurgical retraction

Identifiers

PMID39171445
PMCPMC11792104

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.