Evidence map›Paper›PMID 39171090›Full record

ArticleBiochemia medica2024

The influence of calibration on bias in quality control and patient results for TSH on Vitros XT 7600 analyzer.

Jill Boreyko, Josko Ivica

Abstract read
In one paragraph

Article in Biochemia medica, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Jill BoreykoHamilton Regional Laboratory Medicine Program (HRLMP), Hamilton, Ontario, Canada.
Josko IvicaHamilton Regional Laboratory Medicine Program (HRLMP), Hamilton, Ontario, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Thyroid-stimulating hormone (TSH) is a glycoprotein secreted by the anterior pituitary gland and is regulated by negative feedback from the serum free thyroid hormones. In this study we aimed to quantitate the relative bias caused by calibration drifting as seen in our TSH Levey-Jennings quality control (QC) charts and assess the magnitude of bias on patients' samples. Materials and methods: In the period from October 2021 to August 2022 we looked at the QC results of ten 28-days' calibration time intervals and calculated relative bias compared to the mean. For each time interval the mean from three QC points before and after calibration was calculated. The average from 10 pre- and post-calibration means was calculated and the relative bias, pre- and post-calibration, was then calculated. We used 5 patient samples with low, normal and high TSH concentrations and calculated relative bias pre- and post-calibration. The allowed relative bias for TSH is ± 6.7%. Results: At both QC levels, with the respective means of 5.14 mIU/L (coefficient of variation, CV% = 3.1%) and 27.80 mIU/L (CV% = 3.2%) had their respective relative bias - 8.2% and - 7.9%. The patient samples with low (0.586 mIU/L), normal (2.89 mIU/L and 5.19 mIU/L) and high (20.5 mIU/L and 39.8 mIU/L) TSH had - 4.1%, - 4.0%, - 3.5%, - 5.1% and - 4.1%, respectively. Conclusion: Even though the relative bias exceeded allowable criteria for the QC samples, this was not manifested on the patients' samples.

Indexed as

Quality ControlThyrotropinBiasCalibrationHumansThyrotropinbiasquality managementTSH

Identifiers

PMID39171090
PMCPMC11334199

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked