ArticleIndian journal of orthopaedics2024
Analysis of K-Wire and Olive Wire in Ilizarov Apparatus: A Comparative Study.
Article in Indian journal of orthopaedics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Orthopedic fixators depend on mechanical characteristics like stiffness and firmness. The Ilizarov Apparatus (IA) is a common surgical management approach to restructure the bone fractures. IA includes two wires, specifically K-wire and olive wire, to treat the fractures. Methods: The functions of IA using K-wire and olive wire have been explored with experimental and finite element approach. To describe the stability of fixation and stiffness of olive wire and K-wire, the mechanical performance of the wires was evaluated experimentally as well as numerically by ANSYS software. Results: The results obtained from the olive wire experimental setup with applied loads of 50 to 100 N, showed stiffnesses ranging from 13.85 to 14.58 N/mm and displacements ranging from 3.61 to 6.86 mm. Also, in analytical evaluation, the obtained stiffness ranges from 14.36 to 14.34 N/mm for loads of 50-100 N with a displacement of 3.48-6.97 mm. Conclusions: A two-ring olive wire was found to be stiffer than a two-ring K-wire fixator under the same loading conditions. The goal of this study is to help orthopedic specialists assess the stiffness and stability of IA setups with olive and K-wires.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.