Evidence map›Paper›PMID 39170206›Full record

ArticleHeliyon2024

A novel approach to the quantitative analysis of the particulate matter in conventional cigarette smoke and heated tobacco product aerosols.

E G Tane, L Martínez-Gómez, A Amorós-Pérez, M C Román-Martínez, M A Lillo-Ródenas

Abstract read
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Exposure to Toxic Compounds Using Alternative Smoking Products: Analysis of Empirical Data.International journal of environmental research and public health · 2025
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

E G TaneGrupo MCMA, Departamento de Química Inorgánica e Instituto Universitario de Materiales de Alicante (IUMA), Facultad de Ciencias, Universidad de Alicante, Alicante, E-03080, Spain.
L Martínez-GómezGrupo MCMA, Departamento de Química Inorgánica e Instituto Universitario de Materiales de Alicante (IUMA), Facultad de Ciencias, Universidad de Alicante, Alicante, E-03080, Spain.
A Amorós-PérezGrupo MCMA, Departamento de Química Inorgánica e Instituto Universitario de Materiales de Alicante (IUMA), Facultad de Ciencias, Universidad de Alicante, Alicante, E-03080, Spain.
M C Román-MartínezGrupo MCMA, Departamento de Química Inorgánica e Instituto Universitario de Materiales de Alicante (IUMA), Facultad de Ciencias, Universidad de Alicante, Alicante, E-03080, Spain.
M A Lillo-RódenasGrupo MCMA, Departamento de Química Inorgánica e Instituto Universitario de Materiales de Alicante (IUMA), Facultad de Ciencias, Universidad de Alicante, Alicante, E-03080, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The particulate and soluble matter present in aerosols from combustible cigarettes (CCs) and Heated Tobacco Products (HTPs) was collected in liquid water. These liquids, yellowish in the experiments with cigarettes and colourless after using HTPs, were analysed by Laser Diffraction (LD) and by Transmission Electron Microscopy coupled to Energy Dispersive X-ray spectroscopy (TEM-EDX) to study the amount, size, composition, and other features of the particulate matter (PM) present in the collected aerosols. The particulate matter concentration in HTPs samples is below the limit of quantification for LD, and only samples from cigarettes show a particulate matter concentration above such limit. TEM analysis has revealed that the liquid samples (from both, cigarettes and HTPs experiments) contain particulate matter, mainly composed of carbon (C) and oxygen (O), but also of traces of inorganic elements. The TEM electron beam results in the evaporation of the particulate matter derived from HTPs, but not of that derived from cigarettes, highlighting the different nature of the particulate matter in both systems, i.e. liquid particulate matter present in the HTPs aerosols and solid particulate matter in the cigarettes smoke. A protocol for the quantitative comparison of the particulate matter present in aerosols has been applied over sixteen TEM images for each sample, confirming important differences from the point of view of the amount of particulate matter and particle size ranges. Thus, the amount of particulate matter for HTPs aerosol samples is more than one order of magnitude lower than for cigarettes smoke.

Indexed as

CollectionCombustible cigarettesHCIHeated tobacco productsHeat-not-burn productsIQOSParticulate matterQuantitative analysis

Identifiers

PMID39170206
PMCPMC11336348

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.