Evidence map›Paper›PMID 39169075›Full record

ArticleScientific reports2024

Biomechanical evaluation of Gamma 3 nail with anti-rotation screw fixation for unstable femoral neck fractures: a biomechanical study.

Deyin Liu, Qiang Huang, Chaofeng Wang, Cheng Ren, Yibo Xu, Changjun He, Kun Zhang, Dawei Zhou, Congming Zhang, Teng Ma

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Deyin Liu *Department of Severe and Poly Trauma, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an City, 710054, Shaanxi Province, China.
Qiang Huang *Department of Severe and Poly Trauma, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an City, 710054, Shaanxi Province, China.
Chaofeng Wang *Department of Severe and Poly Trauma, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an City, 710054, Shaanxi Province, China.
Cheng RenDepartment of Severe and Poly Trauma, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an City, 710054, Shaanxi Province, China.
Yibo XuDepartment of Severe and Poly Trauma, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an City, 710054, Shaanxi Province, China.
Changjun HeDepartment of Severe and Poly Trauma, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an City, 710054, Shaanxi Province, China.
Kun ZhangDepartment of Severe and Poly Trauma, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an City, 710054, Shaanxi Province, China.
Dawei ZhouDepartment of Severe and Poly Trauma, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an City, 710054, Shaanxi Province, China.
Congming ZhangDepartment of Severe and Poly Trauma, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an City, 710054, Shaanxi Province, China. zang.cong.ming@163.com.
Teng MaDepartment of Severe and Poly Trauma, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an City, 710054, Shaanxi Province, China. Free40@126.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aims to evaluate the biomechanical performance of the Gamma 3 nail with an anti-rotation screw (GNS) and compare it to two established gold-standard methods for treating unstable femoral neck fractures (UFNFs). Synthetic bone models were prepared with Pauwels' type III osteotomy and an additional posterior wedge. Three different implant configurations were tested: three cannulated crews (3CS) in an inverted triangle configuration, a dynamic hip screw with an anti-rotation screw (DHSS), and GNS. Non-destructive cyclic axial loading was applied at 7° adduction, with 1000 cycles ranging from 100 to 1000 N. Subsequently, a construct failure test was conducted using progressive axial compression, and fracture reduction loss was recorded. The average axial stiffness was 321 ± 52 N/mm for 3CS, 430 ± 71 N/mm for DHSS, and 519 ± 104 N/mm for GNS. The average ultimate failure loads were 2699.3 N for 3CS, 3427.1 N for DHSS, and 3758.9 N for GNS. GNS demonstrated significantly greater axial stiffness compared to the other two groups (P < 0.05). Both DHSS and GNS exhibited similar failure loading, which were greater than those of 3CS (P < 0.05). GNS offers the advantages of a minimally invasive and intramedullary implant with comparable stability to the DHSS system. Moreover, GNS demonstrated superior biomechanical performance compared to 3 CS configuration.

Indexed as

Bone NailsBone ScrewsFemoral Neck FracturesBiomechanical PhenomenaFracture Fixation, InternalHumans

Identifiers

PMID39169075
PMCPMC11339291

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.