Evidence map›Paper›PMID 39168870›Full record

ArticleMikrochimica acta2024

Exploring the influence of silicon oxide microchips shape on cellular uptake using imaging flow cytometry.

Gordon Bruce, Saman Bagherpour, Marta Duch, José Antonio Plaza, Snow Stolnik, Lluïsa Pérez-García

Abstract read
In one paragraph

Article in Mikrochimica acta, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Gordon BruceDivision of Advanced Materials and Healthcare Technologies, School of Pharmacy, University of Nottingham, Nottingham, NG7 2, UK.
Saman BagherpourDepartament de Farmacologia, Facultat de Farmàcia I Ciències de L'Alimentació, Toxicologia I Química Terapèutica, Universitat de Barcelona, Av. Joan XXIII 27-31, 08028, Barcelona, Spain.
Marta DuchInstituto de Microelectrónica de Barcelona IMB-CNM (CSIC), Campus UAB, Cerdanyola del Vallès, 08193, Barcelona, Spain.
José Antonio PlazaInstituto de Microelectrónica de Barcelona IMB-CNM (CSIC), Campus UAB, Cerdanyola del Vallès, 08193, Barcelona, Spain.
Snow StolnikDivision of Regenerative Medicine and Cellular Therapies, School of Pharmacy, University of Nottingham, Nottingham, NG7 2, UK.
Lluïsa Pérez-GarcíaDivision of Advanced Materials and Healthcare Technologies, School of Pharmacy, University of Nottingham, Nottingham, NG7 2, UK. mlperez@ub.edu.ORCID http://orcid.org/0000-0003-2031-4405

Funding

Agaur 2021 SGR 01085Agaur FISDUREngineering and Physical Sciences Research Council EP/L01646XMinisterio de Ciencia e Innovación PID2020-115663GB-C3 1Ministerio de Ciencia e Innovación PID2020-115663GB-C3-2
6 · The paper itself

Abstract

Nano- and micro-carriers of therapeutic molecules offer numerous advantages for drug delivery, and the shape of these particles plays a vital role in their biodistribution and their interaction with cells. However, analysing how microparticles are taken up by cells presents methodological challenges. Qualitative methods like microscopy provide detailed imaging but are time-consuming, whereas quantitative methods such as flow cytometry enable high-throughput analysis but struggle to differentiate between internalised and surface-bound particles. Instead, imaging flow cytometry combines the best of both worlds, offering high-resolution imaging with the efficiency of flow cytometry, allowing for quantitative analysis at the single-cell level. This study focuses on fluorescently labelled silicon oxide microchips of various morphologies but related surface areas and volumes: rectangular cuboids and apex-truncated square pyramid microchips fabricated using photolithography techniques, offering a reliable basis for comparison with the more commonly studied spherical particles. Imaging flow cytometry was utilised to evaluate the effect of particle shape on cellular uptake using RAW 264.7 cells and revealed phagocytosis of particles with all shapes. Increasing the particle dose enhanced the uptake, while macrophage stimulation had minimal effect. Using a ratio particle:cell of 10:1 cuboids and spheres showed an uptake rate of approximately 50%, in terms of the percentage of cells with internalised particles, and the average number of particles taken up per cell ranging from about 1-1.5 particle/cell for all the different shapes. This study indicates how differently shaped micro-carriers offer insights into particle uptake variations, demonstrating the potential of non-spherical micro-carriers for precise drug delivery applications.

Indexed as

Flow CytometrySilicon DioxideAnimalsFluorescent DyesMacrophagesMiceParticle SizePhagocytosisRAW 264.7 CellsFluorescent DyesSilicon DioxideCellular uptakeFluorescence labelFunctionalizationImaging flow cytometryMicrofabricationSilicon oxide microchips

Identifiers

PMID39168870
PMCPMC11339096

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.