ArticleAnnals of intensive care2024

Modes of administration of nitric oxide devices and ventilators flow-by impact the delivery of pre-determined concentrations.

Alice Vuillermoz, Mathilde Lefranc, Nathan Prouvez, Clément Brault, Yoann Zerbib, Mary Schmitt, Jean-Marie Forel, Mathieu Le Tutour, Arnaud Lesimple, Alain Mercat and 2 more

Abstract read
In one paragraph

Article in Annals of intensive care, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Alice Vuillermoz *Vent'Lab, Medical Intensive Care Unit, University Hospital of Angers, Angers, France.
Mathilde Lefranc *Vent'Lab, Medical Intensive Care Unit, University Hospital of Angers, Angers, France.
Nathan ProuveziNOSystems, Antony, France.
Clément BraultMedical Intensive Care Unit, Amiens University Hospital, Amiens, France.
Yoann ZerbibMedical Intensive Care Unit, Amiens University Hospital, Amiens, France.
Mary SchmittAir Liquide Santé International, Bagneux, France.
Jean-Marie ForelMedical Intensive Care Unit, APHM Hôpital Nord, Marseille, France.
Mathieu Le TutourVent'Lab, Medical Intensive Care Unit, University Hospital of Angers, Angers, France.
Arnaud LesimpleVent'Lab, Medical Intensive Care Unit, University Hospital of Angers, Angers, France.
Alain MercatVent'Lab, Medical Intensive Care Unit, University Hospital of Angers, Angers, France.
Jean-Christophe Richard *Vent'Lab, Medical Intensive Care Unit, University Hospital of Angers, Angers, France.
François M Beloncle *Vent'Lab, Medical Intensive Care Unit, University Hospital of Angers, Angers, France. francois.beloncle@univ-angers.fr.ORCID http://orcid.org/0000-0002-0590-459X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundNitric oxide (NO) is a strong vasodilator, selectively directed on pulmonary circulation through inhaled administration. In adult intensive care units (ICU), it is mainly used for refractory hypoxemia in mechanically ventilated patients. Several medical delivery devices have been developed to deliver inhaled nitric oxide (iNO). The main purpose of those devices is to guarantee an accurate inspiratory NO concentration, whatever the ventilator used, with NO

methodsWe tested seven iNO-devices on a test-lung connected to distinct ICU ventilators offering four different levels of flow-by. We measured the flow in the inspiratory limb of the patient circuit and the airway pressure. The nitric oxide/nitrogen (NO/N

resultsWe identified three iNO-device generations based on the way they deliver NO flow: "Continuous", "Sequential to inspiratory phase" (I-Sequential) and "Proportional to inspiratory and expiratory ventilator flow" (Proportional). Median accuracy of iNO concentration measured in the test lung was 2% (interquartile range, IQR -19; 36), -23% (IQR -29; -17) and 0% (IQR -2; 0) with Continuous, I-Sequential and Proportional devices, respectively. Increased ventilator flow-by resulted in decreased iNO concentration in the test-lung with Continuous and I-Sequential devices, but not with Proportional ones. NO

conclusionWe identified three different generations of iNO-devices, based on their gas administration modalities, that were associated with highly variable iNO concentrations' accuracy. Ventilator's flow by significantly impacted iNO concentration. Only the Proportional devices permitted to accurately deliver iNO whatever the conditions and the ventilators tested.

Indexed as

Acute respiratory distress syndromeArtificial lungBias flowbyflowICU ventilatorsInhaled nitric oxideiNO delivery systemsMechanical ventilationVentilator flow-by

Identifiers

PMID39167232
PMCPMC11339004

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.