Evidence map›Paper›PMID 39166946›Full record

ArticleACS sensors2024

Continuous Biosensor Based on Particle Motion: How Does the Concentration Measurement Precision Depend on Time Scale?

Rafiq M Lubken, Yu-Ting Lin, Stijn R R Haenen, Max H Bergkamp, Junhong Yan, Paul A Nommensen, Menno W J Prins

Abstract read
In one paragraph

Article in ACS sensors, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Rafiq M LubkenHelia Biomonitoring, Eindhoven 5612 AR, The Netherlands.ORCID 0000-0001-7554-1141
Yu-Ting LinHelia Biomonitoring, Eindhoven 5612 AR, The Netherlands.ORCID 0000-0003-3235-9491
Stijn R R HaenenHelia Biomonitoring, Eindhoven 5612 AR, The Netherlands.
Max H BergkampHelia Biomonitoring, Eindhoven 5612 AR, The Netherlands.ORCID 0000-0001-8904-4322
Junhong YanHelia Biomonitoring, Eindhoven 5612 AR, The Netherlands.
Paul A NommensenAvebe Innovation Center, Groningen 9747 AA, The Netherlands.ORCID 0009-0005-3390-2689
Menno W J PrinsHelia Biomonitoring, Eindhoven 5612 AR, The Netherlands.ORCID 0000-0002-9788-7298

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Continuous biosensors measure concentration-time profiles of biomolecular substances in order to allow for comparisons of measurement data over long periods of time. To make meaningful comparisons of time-dependent data, it is essential to understand how measurement imprecision depends on the time interval between two evaluation points, as the applicable imprecision determines the significance of measured concentration differences. Here, we define a set of measurement imprecisions that relate to different sources of variation and different time scales, ranging from minutes to weeks, and study these using statistical analyses of measurement data. The methodology is exemplified for Biosensing by Particle Motion (BPM), a continuous, affinity-based sensing technology with single-particle and single-molecule resolution. The studied BPM sensor measures specific small molecules (glycoalkaloids) in an industrial food matrix (potato fruit juice). Measurements were performed over several months at two different locations, on nearly 50 sensor cartridges with in total more than 1000 fluid injections. Statistical analyses of the measured signals and concentrations show that the relative residuals are normally distributed, allowing extraction and comparisons of the proposed imprecision parameters. The results indicate that sensor noise is the most important source of variation followed by sample pretreatment. Variations caused by fluidic transport, changes of the sensor during use (drift), and variations due to different sensor cartridges and cartridge replacements appear to be small. The imprecision due to sensor noise is recorded over few-minute time scales and is attributed to stochastic fluctuations of the single-molecule measurement principle, false-positive signals in the signal processing, and nonspecific interactions. The developed methodology elucidates both time-dependent and time-independent factors in the measurement imprecision, providing essential knowledge for interpreting concentration-time profiles as well as for further development of continuous biosensing technologies.

Indexed as

Biosensing TechniquesFruit and Vegetable JuicesMotionSolanum tuberosumTime Factorsaffinity-based sensinganalytical performancecontinuous biosensingcontinuous monitoringmeasurement precision

Identifiers

PMID39166946
PMCPMC11443519

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.