Evidence map›Paper›PMID 39166502›Full record

Trial reportAnaesthesiology intensive therapy2024

Comparison between Air-Q Self Pressurized Airway Device with Blocker and Proseal Laryngeal Mask Airway in anesthetized paralyzed adult female patients undergoing elective gynecological operations.

Maha Mohammed Ismail Youssef, Naser Mohammed Dobal, Yahya Mohamed Hammad, Nesrine Abdel Rahman El-Refai, Reham Ali Abdelhaleem Abdelrahman

Abstract readRandomized Controlled TrialComparative Study
In one paragraph

Trial report in Anaesthesiology intensive therapy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Maha Mohammed Ismail YoussefDepartment of Anesthesia, Surgical ICU and Pain Management, Faculty of Medicine, Cairo University, Cairo, Egypt.
Naser Mohammed DobalDepartment of Anesthesia, Surgical ICU and Pain Management, Faculty of Medicine, Cairo University, Cairo, Egypt.
Yahya Mohamed HammadDepartment of Anesthesia, Surgical ICU and Pain Management, Faculty of Medicine, Cairo University, Cairo, Egypt.
Nesrine Abdel Rahman El-RefaiDepartment of Anesthesia, Surgical ICU and Pain Management, Faculty of Medicine, Cairo University, Cairo, Egypt.
Reham Ali Abdelhaleem AbdelrahmanDepartment of Anesthesia, Surgical ICU and Pain Management, Faculty of Medicine, Cairo University, Cairo, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe Air-Q Self Pressurized Airway Device with Blocker (SP Blocker) was compared to the Proseal Laryngeal Mask Airway (PLMA) during positive pressure ventilation regarding the primary outcome (oropharyngeal leak pressure [OLP]), secondary outcomes (peak inspiratory pressure [PIP], inspired tidal volume [ITV], expired tidal volume [ETV], leak volume [LV] and leak fraction [LF]), insertion time, ventilation score, fiber-optic glottis view score, and postoperative laryngopharyngeal parameters (LPM). MATERIAL AND

methodsAdult healthy female patients scheduled for elective gynecological laparotomies under general anesthesia using controlled mechanical ventilation were recruited to a prospective randomized comparative clinical trial. Exclusion criteria were body mass index (BMI) ≥ 35 kg m -2 , El-Ganzouri score ≥ 5, upper airway problems, hiatus hernia or pregnancy. Patients were classified into an SP Blocker group ( n = 75) and a PLMA group ( n = 75). Primary and secondary outcomes were assessed initially and at fixed time points after successful insertion of devices.

resultsInitially after successful device insertion: the SP Blocker group showed statistically significant higher mean OLP (cmH 2 O) (29.46 ± 2.11 vs. 28.06 ± 1.83 respectively; 95% CI: -2.037 to -0.76, P < 0.0001), lower mean PIP (cmH 2 O) (15.49 ± 0.61 vs. 17.78 ± 1.04 respectively; 95% CI: 2.02 to 2.56, P < 0.0001), higher mean ITV (mL) (411 ± 30 vs. 403 ± 15 respectively; 95% CI: -15.65 to -0.347, P = 0.041), higher mean ETV (mL) (389 ± 12 vs. 354 ± 11 respectively; 95% CI: -38.72 to -31.29, P < 0.0001), lower mean LV (mL) (22 ± 18 vs. 49 ± 10 respectively; 95% CI: 22.3 to 31.7, P < 0.0001) and lower mean LF (%) (5 ± 2.04 vs. 12 ± 6.8 respectively; 95% CI: 5.38 to 8.62, P < 0.0001) than the PLMA group. Mean insertion time (seconds) was shorter in the SP Blocker group than the PLMA group (16.39 ± 2.81 vs. 18.63 ± 3.44 respectively; 95% CI: 1.23 to 3.25, P < 0.0001). The SP Blocker group offered a better fiber-optic glottis view score than the PLMA group without differences concerning ventilation score and LPM.

conclusionsSP Blocker provided as safe anesthesia during controlled mechanical ventilation as PLMA.

Indexed as

Anesthesia, GeneralGynecologic Surgical ProceduresLaryngeal MasksAdultElective Surgical ProceduresFemaleHumansMiddle AgedParalysisPositive-Pressure RespirationProspective Studiesfiber-optic view score of glottislaryngopharyngeal morbidityleak fractionoropharyngeal leak pressuresupraglottic airway devices

Identifiers

PMID39166502
PMCPMC11284585

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.