Evidence map›Paper›PMID 39164475›Full record

ArticleSpine deformity2024

Axial rod slip at the end-of-construct screw in scoliosis surgery: relevance, occurrence and prevention.

T P Schlösser, I Blaauw, M R van der Valk, Guido van Solinge, C Faber, M C Kruyt

Abstract readMulticenter Study
In one paragraph

Article in Spine deformity, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

T P SchlösserDepartment of Orthopedic Surgery, University Medical Center Utrecht, P. O. Box 85500, 3508, Utrecht, GA, The Netherlands. T.P.C.Schlosser@umcutrecht.nl.ORCID 0000-0003-1517-5914
I BlaauwDepartment of Orthopedic Surgery, University Medical Center Utrecht, P. O. Box 85500, 3508, Utrecht, GA, The Netherlands.
M R van der ValkDepartment of Orthopedic Surgery, University Medical Center Utrecht, P. O. Box 85500, 3508, Utrecht, GA, The Netherlands.
Guido van SolingeDepartment of Orthopedics Isala, Zwolle, The Netherlands.
C FaberDepartment of Orthopedics UMC Groningen, Groningen, The Netherlands.
M C KruytDepartment of Orthopedic Surgery, University Medical Center Utrecht, P. O. Box 85500, 3508, Utrecht, GA, The Netherlands. m.c.kruyt@umcutrecht.nl.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeDespite standardized biomechanical tests for spinal implants, we recently recognized pedicle screw failure to maintain the rod fixated as a clinical concern in scoliosis surgery. This occurrence study investigates the risk and magnitude of axial rod slip (ARS), its relation with technique and preventive measures.

methodsRetrospective multicenter review of all primary scoliosis cases (2018-2020) with > 1 year FU from three centers, instrumented with uniplanar screws and 5.5 mm CoCr rods (Mesa 2, Stryker Corporation, Kalamazoo, MI, USA). ARS was defined as > 1 mm change in residual distal rod length from the screw in the lowest instrumented vertebra (LIV) and assessed by two independent observers. Slip distance, direction, relation to distal screw density and time of observation were recorded, as well as the effect of ARS on caudal curve increase. To prevent slip, more recent patients were instrumented with a different end-of-construct screw (Reline, NuVasive Inc. San Diego, CA, USA) and analyzed for comparison.

resultsARS risk was 27% (56/205) with a distance of 3.6 ± 2.2 mm, predominantly convex. 42% occurred before 4 months, the rest before 1 year. The caudal curve substantially increased three times more often in patients with ARS. Interobserver reliability was high and slip was in the expected direction. ARS was unrelated to distal screw density. Remarkable variation in ARS rates (53%, 31%, 13%) existed between the centers, while there was no difference in mean screw density (≈1.3 screws/level) or curve correction (≈60%). Revision surgery for ARS was required in 2.9% (6/207). Using the different end-of-construct screw, ARS risk was only 2% (1/56) and no revisions were required.

conclusionThis study demonstrates the prevalence of axial rod slip at the end of construct in scoliosis surgery and its clinical relevance. While minimal ARS can be subclinical, ARS should not be mistaken for adding on. The most severe ARS predominantly occurred convex at the high-loaded distal screw when L3 was the LIV. Longer constructs (LIV L3 or L4) have a higher risk of ARS. The minimal risk of ARS with another end-of-construct screw underscores the influence of screw type on ARS occurrence in our series. Further research is essential to refine techniques and enhance patient outcomes.

Indexed as

Pedicle ScrewsScoliosisSpinal FusionAdolescentChildFemaleHumansMalePostoperative ComplicationsRetrospective StudiesAdolescent idiopathic scoliosisMesa 2 deformityPedicle screwSlip

Identifiers

PMID39164475
PMCPMC11499526

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.