Evidence map›Paper›PMID 39160668›Full record

Trial reportHip international : the journal of clinical and experimental research on hip pathology and therapy2024

Comparison of 5-year cup and stem migration between ceramic-on-ceramic and ceramic-on-polyethylene bearing in press-fit total hip arthroplasty: a randomised controlled trial using radiostereometric analysis.

Amanda D Klaassen, Justin van Loon, Nienke W Willigenburg, Lennard A Koster, Bart L Kaptein, Victor P M van der Hulst, Daniel Haverkamp, Dirk Jan F Moojen, Rudolf W Poolman

Registry-linked trialAbstract readRandomized Controlled TrialComparative Study
In one paragraph

Trial report in Hip international : the journal of clinical and experimental research on hip pathology and therapy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03093038 (Early Stability of the Delta-TT Cup With Polyethylene Insert Compared to the Delta-TT Cup With Ceramic Insert. A Randomised RSA Study), which is not on this map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03093038 nacompletednot on this map

Early Stability of the Delta-TT Cup With Polyethylene Insert Compared to the Delta-TT Cup With Ceramic Insert. A Randomised RSA Study

TypeinterventionalSponsorJointResearchRan2014 to 2021Enrolled70ConditionsOsteoarthrosisArmsH-MAX stem & Delta-TT cup + polyethylene, H-MAX stem & Delta-TT cup + ceramic, C2 stem & Delta-TT cup + ceramic
3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Amanda D KlaassenDepartment of Orthopaedic Surgery, OLVG, Amsterdam, the Netherlands.ORCID 0000-0002-8499-2814
Justin van LoonDepartment of Orthopaedic Surgery, OLVG, Amsterdam, the Netherlands.ORCID 0000-0001-5009-1500
Nienke W WilligenburgDepartment of Orthopaedic Surgery, OLVG, Amsterdam, the Netherlands.
Lennard A KosterDepartment of Orthopaedic Surgery, LUMC, Leiden, the Netherlands.
Bart L KapteinDepartment of Orthopaedic Surgery, LUMC, Leiden, the Netherlands.
Victor P M van der HulstDepartment of Radiology, OLVG, Amsterdam, the Netherlands.
Daniel HaverkampXpert Clinics Orthopedie Amsterdam, the Netherlands.
Dirk Jan F MoojenDepartment of Orthopaedic Surgery, OLVG, Amsterdam, the Netherlands.
Rudolf W PoolmanDepartment of Orthopaedic Surgery, OLVG, Amsterdam, the Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe inelasticity of ceramic bearings might affect primary stability and migration of implants in press-fit total hip arthroplasty (THA). This randomised controlled trial compares migration patterns of the uncemented Delta-TT cup and H-MAX S stem between ceramic and polyethylene liners, up to 5 years follow-up.

methodsPatients receiving primary press-fit THA were randomly allocated to a ceramic (

resultsAt 5-year follow-up, mean (95% CI) proximal cup translation was 0.56 (0.37-0.74) mm in ceramic and 0.58 (0.25-0.90) mm in polyethylene (

conclusions5-year migration patterns of press-fit cups and stems were similar between ceramic and polyethylene liners. The Delta-TT cup and H-MAX S stem showed secondary stabilisation and remained stable up to 5 years in both groups, which is promising for long-term survival with both liner types. CLINICAL

trial registrationClinicalTrials.gov (NCT03093038).

Indexed as

Arthroplasty, Replacement, HipCeramicsHip ProsthesisPolyethyleneProsthesis DesignProsthesis FailureRadiostereometric AnalysisAdultAgedFemaleFollow-Up StudiesHumansMaleMiddle AgedTime FactorsPolyethyleneCeramicmigrationpolyethyleneradiostereometric analysistotal hip arthroplasty

Identifiers

PMID39160668
PMCPMC11629593

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.