ArticleTransplantation2025

Five-day Wearable Respiratory Support With a Novel Ambulatory Pulmonary Assist System in an Awake Ovine Model.

Yeahwa Hong, Suji Shin, Umar Nasim, Helen M Scala, Kalliope G Roberts, Alexander S Potchernikov, Brian E Woolley, David J Skoog, Matthew Bacchetta, Keith E Cook

Abstract read
In one paragraph

Article in Transplantation, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Yeahwa HongDepartment of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA.
Suji ShinDepartment of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA.
Umar NasimDepartment of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA.
Helen M ScalaDepartment of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA.
Kalliope G RobertsDepartment of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA.
Alexander S PotchernikovDepartment of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA.
Brian E WoolleyDepartment of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA.
David J SkoogAdvanced Respiratory Technologies Inc, Pittsburgh, PA.
Matthew BacchettaDepartment of Cardiac Surgery, Vanderbilt University Medical Center, Nashville, TN.
Keith E CookDepartment of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA.

Funding

Cardiothoracic Surgery Research Training ProgramT32HL160526 · NHLBI · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI JAMES D LUKETICH, Julie A Phillippi · 2022 to 2026
$1.5M
NHLBI NIH HHS T32 HL160526
6 · The paper itself

Abstract

backgroundThe pulmonary assist system (PAS) is a wearable respiratory support system that is currently under development for patients with chronic lung disease as a bridge to lung transplantation or as destination therapy. This study evaluates the long-term performance and biocompatibility of the PAS in a 5-d awake, ovine model.

methodsThe PAS was attached to normal sheep in venovenous configuration. Components of the PAS included a 0.9 m 2 surface area oxygenator and a lightweight, battery-powered axial flow pump. The system was also tested using the Abbott PediMag as the control pump. Each sheep was supported on the PAS for 5 d with 2 L/min blood flow and 4 L/min sweep gas. Activated clotting times of 200-240 s were maintained using intravenous heparin. Pump performance, oxygen transfer, oxygenator resistance, and hematologic parameters were measured throughout the support.

resultsThe PAS, either using the axial flow pump or PediMag (n = 4 each), was well tolerated by the sheep without signs of device-related organ damage or hemolysis. All the studies achieved the full, 5-d study duration. The oxygenator resistance remained consistent without significant clot formation in all experiments with an average resistance of 2.55 ± 0.10 mm Hg/(L/min). The system achieved an average oxygen transfer rate of 116.4 ± 5.5 mL/min, with an average Hb concentration of 9.2 ± 0.6 g/dL. White blood cell, platelet, and hematocrit levels also remained stable and within normal limits throughout the study period.

conclusionsThe PAS provided 5 d of uncomplicated ambulatory respiratory support with minimal clot formation, stable gas exchange, blood flow resistance, and hematologic parameters.

Indexed as

Wearable Electronic DevicesAnimalsDisease Models, AnimalEquipment DesignModels, AnimalSheepSheep, DomesticTime FactorsWakefulness

Identifiers

PMID39160653
PMCPMC11839337

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.