Evidence map›Paper›PMID 39160438›Full record

ArticleAnalytical and bioanalytical chemistry2024

Development and validation of the UHPLC-MS/MS method for the quantitative determination of 25 PFAS in dried blood spots.

Martina Galletto, Christina Ververi, Marta Massano, Eugenio Alladio, Marco Vincenti, Alberto Salomone

Abstract readValidation Study
In one paragraph

Article in Analytical and bioanalytical chemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Martina GallettoDepartment of Chemistry, University of Turin, Turin, Italy. martina.galletto@unito.it.ORCID http://orcid.org/0009-0001-1186-6390
Christina VerveriDepartment of Chemistry, University of Turin, Turin, Italy.
Marta MassanoDepartment of Chemistry, University of Turin, Turin, Italy.
Eugenio AlladioDepartment of Chemistry, University of Turin, Turin, Italy.
Marco VincentiDepartment of Chemistry, University of Turin, Turin, Italy.
Alberto SalomoneDepartment of Chemistry, University of Turin, Turin, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Per- and polyfluoroalkyl substances (PFAS) are anthropogenic fluorine-containing compounds largely used in industrial and consumer applications. They tend to bioaccumulate in the human body after intake from various sources in daily life. Following repeated exposure to PFAS, a broad range of adverse health outcomes has been reported. Consequently, monitoring PFAS levels in human blood is of paramount importance for public health policies. In contrast with traditional venipuncture, dried blood spots (DBS) constitute a reliable, cheap, and less invasive technique to allow microsampling by capillary blood collected on a specific device. This work aimed to develop and validate an innovative analytical method, combining quantitative DBS with UHPLC-MS/MS instrumentation to identify and quantify 25 PFAS. The extraction procedure was developed and optimized within the range 2-100 ng/mL. Specifically, fortified blood was applied on Capitainer®B devices providing 10 μL of blood volume through a microfluidic channel. After 3 h of drying, the extraction was performed by methanol under sonication, followed by centrifugation. Then, the extraction solvent was evaporated; the residue was reconstituted with the mobile phase solution. The validated method evidenced good sensitivity, with limits of detection ranging from 0.4 ng/mL (PFODA, PFOS) to 1.0 ng/mL (PFOA, 3,6-OPFHpA). The ± 20% acceptability criteria established for intra- and inter-day precision and accuracy were fulfilled for all analytes. High recovery-above 80%-was recorded, whereas significant matrix effect resulted in ion enhancement (> 50%) for 13 analytes. In conclusion, the proposed workflow proved to be reliable, fit for purpose, and easily adaptable in the laboratory routine.

Indexed as

Dried Blood Spot TestingFluorocarbonsLimit of DetectionTandem Mass SpectrometryChromatography, High Pressure LiquidHumansReproducibility of ResultsFluorocarbonsDBSHealth monitoringOccupational exposurePFASUHPLC-MS/MS

Identifiers

PMID39160438
PMCPMC11493788

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.