Evidence map›Paper›PMID 39160154›Full record

ArticleLight, science & applications2024

Wavelength-multiplexed multi-mode EUV reflection ptychography based on automatic differentiation.

Yifeng Shao, Sven Weerdenburg, Jacob Seifert, H Paul Urbach, Allard P Mosk, Wim Coene

Abstract read
In one paragraph

Article in Light, science & applications, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Ultrafast Dynamic Defect Inspection With Computational Neuromorphic Imaging.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Article
  6. Article
  7. Review
  8. Uncertainty-aware Fourier ptychography.Light, science & applications · 2025
    Article
  9. Article
  10. Ptychography at all wavelengths.Nature reviews. Methods primers · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yifeng Shao *Imaging Physics Department, Applied Science Faculty, Delft University of Technology, Lorentzweg 1, Delft, 2628 CJ, The Netherlands. Y.Shao@tudelft.nl.ORCID http://orcid.org/0000-0003-4652-6051
Sven Weerdenburg *Imaging Physics Department, Applied Science Faculty, Delft University of Technology, Lorentzweg 1, Delft, 2628 CJ, The Netherlands.ORCID http://orcid.org/0000-0002-8966-9557
Jacob Seifert *Nanophotonics, Debye Institute for Nanomaterials Science and Center for Extreme Matter and Emergent Phenomena, Utrecht University, P.O. Box 80000, Utrecht, 3508 TA, The Netherlands.
H Paul UrbachImaging Physics Department, Applied Science Faculty, Delft University of Technology, Lorentzweg 1, Delft, 2628 CJ, The Netherlands.
Allard P MoskNanophotonics, Debye Institute for Nanomaterials Science and Center for Extreme Matter and Emergent Phenomena, Utrecht University, P.O. Box 80000, Utrecht, 3508 TA, The Netherlands.ORCID http://orcid.org/0000-0002-1140-6626
Wim CoeneImaging Physics Department, Applied Science Faculty, Delft University of Technology, Lorentzweg 1, Delft, 2628 CJ, The Netherlands.ORCID http://orcid.org/0000-0002-4894-6044

Funding

Nederlandse Organisatie voor Wetenschappelijk Onderzoek (Netherlands Organisation for Scientific Research) P16-08
6 · The paper itself

Abstract

Ptychographic extreme ultraviolet (EUV) diffractive imaging has emerged as a promising candidate for the next generationmetrology solutions in the semiconductor industry, as it can image wafer samples in reflection geometry at the nanoscale. This technique has surged attention recently, owing to the significant progress in high-harmonic generation (HHG) EUV sources and advancements in both hardware and software for computation. In this study, a novel algorithm is introduced and tested, which enables wavelength-multiplexed reconstruction that enhances the measurement throughput and introduces data diversity, allowing the accurate characterisation of sample structures. To tackle the inherent instabilities of the HHG source, a modal approach was adopted, which represents the cross-density function of the illumination by a series of mutually incoherent and independent spatial modes. The proposed algorithm was implemented on a mainstream machine learning platform, which leverages automatic differentiation to manage the drastic growth in model complexity and expedites the computation using GPU acceleration. By optimising over 200 million parameters, we demonstrate the algorithm's capacity to accommodate experimental uncertainties and achieve a resolution approaching the diffraction limit in reflection geometry. The reconstruction of wafer samples with 20-nm high patterned gold structures on a silicon substrate highlights our ability to handle complex physical interrelations involving a multitude of parameters. These results establish ptychography as an efficient and accurate metrology tool.

Identifiers

PMID39160154
PMCPMC11333750

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.