ArticleJournal of clinical monitoring and computing2025
Feasibility study of the use of a wearable vital sign patch in an intensive care unit setting.
Article in Journal of clinical monitoring and computing, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Article
- Article
- Enhancing the Usability of Patient Monitoring Devices in Intensive Care Units: Usability Engineering Processes for Early Warning System (EWS) Evaluation and Design.Journal of clinical medicine · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Multiple studies and review papers have concluded that early warning systems have a positive effect on clinical outcomes, patient safety and clinical performances. Despite the substantial evidence affirming the efficacy of EWS applications, persistent barriers hinder their seamless integration into clinical practice. Notably, EWS, such as the National Early Warning Score, simplify multifaceted clinical conditions into singular numerical indices, thereby risking the oversight of critical clinical indicators and nuanced fluctuations in patients' health status. Furthermore, the optimal deployment of EWS within clinical contexts remains elusive. Manual assessment of EWS parameters exacts a significant temporal toll on healthcare personnel. Addressing these impediments necessitates innovative approaches. In this regard, wearable medical technologies emerge as promising solutions capable of continual monitoring of hospitalized patients' vital signs. To overcome the barriers of the use of early warning scores, wearable medical technology has the potential to continuously monitor vital signs of hospitalised patients. However, a fundamental inquiry arises regarding the comparability of their reliability to the current used golden standards. This inquiry underscores the imperative for rigorous evaluation and validation of wearable medical technologies to ascertain their efficacy in augmenting extant clinical practices. This prospective, single-center study aimed to evaluate the accuracy of heart rate and respiratory rate measurements obtained from the Vivalink Cardiac patch in comparison to the ECG-based monitoring system utilized at AZ Maria Middelares Hospital in Ghent. Specifically, the study focused on assessing the concordance between the data obtained from the Vivalink Cardiac patch and the established ECG-based monitoring system among a cohort of ten post-surgical intensive care unit (ICU) patients. Of these patients, five were undergoing mechanical ventilation post-surgery, while the remaining five were not. The study proceeded by initially comparing the data recorded by the Vivalink Cardiac patch with that of the ECG-based monitoring system. Subsequently, the data obtained from both the Vivalink Cardiac patch and the ECG-based monitoring system were juxtaposed with the information derived from the ventilation machine, thereby providing a comprehensive analysis of the patch's performance in monitoring vital signs within the ICU setting. For heart rate, the Vivalink Cardiac patch was on average within a 5% error range of the ECG-based monitoring system during 85.11±10.81% of the measured time. For respiratory rate this was during 40.55±17.28% of the measured time. Spearman's correlation coefficient showed a very high correlation of
Indexed as
Identifiers
39158782What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.