Evidence map›Paper›PMID 39158682›Full record

ArticleNetherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation2024

Trends in adoption of extravascular cardiac implantable electronic devices: the Dutch cohort.

Karel T N Breeman, Reinoud E Knops, Michelle D van der Stoel, Lucas V A Boersma, Sing-Chien Yap, Lieselot van Erven, Vincent F van Dijk, Alexander H Maass, Arthur A M Wilde, Fleur V Y Tjong and 1 more

Abstract read
In one paragraph

Article in Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Karel T N BreemanDepartment of Cardiology, Amsterdam UMC location AMC, Amsterdam, The Netherlands. k.t.breeman@amsterdamumc.nl.ORCID http://orcid.org/0000-0001-8637-2099
Reinoud E KnopsDepartment of Cardiology, Amsterdam UMC location AMC, Amsterdam, The Netherlands.
Michelle D van der StoelNetherlands Heart Registration, Utrecht, The Netherlands.
Lucas V A BoersmaDepartment of Cardiology, Amsterdam UMC location AMC, Amsterdam, The Netherlands.
Sing-Chien YapDepartment of Cardiology, Erasmus MC, Cardiovascular Institute, Thorax Center, Rotterdam, The Netherlands.
Lieselot van ErvenDepartment of Cardiology, Leiden University Medical Center, Leiden, The Netherlands.
Vincent F van DijkDepartment of Cardiology, St Antonius Hospital, Nieuwegein, The Netherlands.
Alexander H MaassDepartment of Cardiology, University Medical Center Groningen, Groningen, The Netherlands.
Arthur A M WildeDepartment of Cardiology, Amsterdam UMC location AMC, Amsterdam, The Netherlands.
Fleur V Y TjongDepartment of Cardiology, Amsterdam UMC location AMC, Amsterdam, The Netherlands.
Device Registration Committee of the Netherlands Heart Registration

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionConventional implantable cardioverter-defibrillators (ICDs) and pacemakers carry a risk of pocket- and lead-related complications in particular. To avoid these complications, extravascular devices (EVDs) have been developed, such as the subcutaneous ICD (S-ICD) and leadless pacemaker (LP). However, data on patient or centre characteristics related to the actual adoption of EVDs are lacking.

objectiveTo assess real-world nationwide trends in EVD adoption in the Netherlands.

methodsUsing the Netherlands Heart Registration, all consecutive patients with a de novo S‑ICD or conventional single-chamber ICD implantation between 2012-2020, or de novo LP or conventional single-chamber pacemaker implantation between 2014-2020 were included. Trends in adoption are described for various patient and centre characteristics.

resultFrom 2012-2020, 2190 S‑ICDs and 10,683 conventional ICDs were implanted; from 2014-2020, 712 LPs and 11,103 conventional pacemakers were implanted. The general use has increased (S-ICDs 8 to 21%; LPs 1 to 8%), but this increase seems to have reached a plateau. S‑ICD recipients were younger than conventional ICD recipients (p < 0.001) and more often female (p < 0.001); LP recipients were younger than conventional pacemaker recipients (p < 0.001) and more often male (p = 0.03). Both S‑ICDs and LPs were mainly implanted in high-volume centres with cardiothoracic surgery on-site, although over time S‑ICDs were increasingly implanted in centres without cardiothoracic surgery (p < 0.001).

conclusionThis nationwide study demonstrated a relatively quick adoption of innovative EVDs with a plateau after approximately 4 years. S‑ICD use is especially high in younger patients. EVDs are mainly implanted in high-volume centres with cardiothoracic surgery back-up, but S‑ICD use is expanding beyond those centres.

Indexed as

AdoptionExtravascularLeadless pacemakerRegistrationSubcutaneous ICD

Identifiers

PMID39158682
PMCPMC11413308

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked