Evidence map›Paper›PMID 39158389›Full record

ArticleClinical orthopaedics and related research2025

Are There Differences in Performance Among Femoral Stem Brands Utilized in Cementless Hemiarthroplasty for Treatment of Geriatric Femoral Neck Fractures?

Ishan Shah, Heather A Prentice, Kanu Okike, Ronald A Navarro, Brian H Fasig, Elizabeth W Paxton, Christopher D Grimsrud

Abstract readComparative Study
In one paragraph

Article in Clinical orthopaedics and related research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ishan ShahDepartment of Orthopaedic Surgery, St. Mary's Medical Center, San Francisco, CA, USA.
Heather A PrenticeMedical Device Surveillance & Assessment, Kaiser Permanente, San Diego, CA, USA.
Kanu OkikeDepartment of Orthopaedic Surgery, Hawaii Permanente Medical Group, Honolulu, HI, USA.
Ronald A NavarroDepartment of Orthopaedic Surgery, Southern California Permanente Medical Group, Harbor City, CA, USA.ORCID 0000-0003-1869-6440
Brian H FasigMedical Device Surveillance & Assessment, Kaiser Permanente, San Diego, CA, USA.
Elizabeth W PaxtonMedical Device Surveillance & Assessment, Kaiser Permanente, San Diego, CA, USA.
Christopher D GrimsrudDepartment of Orthopaedic Surgery, The Permanente Medical Group, Oakland, CA, USA.ORCID 0000-0003-2367-6401

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFor the vast majority of displaced femoral neck fractures in older patients, cemented femoral fixation is indicated because it is associated with a lower risk of periprosthetic fracture than cementless fixation. Nevertheless, cementless fixation continues to be utilized with high frequency for hip fractures in the United States. It is therefore helpful to understand the performance of individual cementless brands and models. Although prior studies have compared femoral stems by design type or stem geometry, there may still be a difference in revision risk according to femoral stem brand given the potential differences within design groupings with regard to manufacturing, implantation systems, and implant design nuances among vendors. QUESTIONS/PURPOSES: (1) Is there a difference in aseptic revision risk among femoral stem brands in patients ≥ 60 years of age who have displaced femoral neck fractures treated with cementless hemiarthroplasty? (2) Is there a difference in revision for periprosthetic fracture among femoral stem brands in patients ≥ 60 years of age with displaced femoral neck fractures treated with cementless hemiarthroplasty?

methodsA retrospective, comparative, large-database cohort study was conducted using data from Kaiser Permanente's Hip Fracture Registry. This integrated healthcare system covers more than 12 million members throughout eight regions in the United States; membership has been found to be representative of the general population in the areas served. The Hip Fracture Registry collects details on all patients who undergo hip fracture repair within the organization. These patients are then longitudinally monitored for outcomes after their repair, and all identified outcomes are manually validated through chart review. Patients ages ≥ 60 years who underwent unilateral hemiarthroplasty treatment of a displaced femoral neck fracture from 2009 to 2021 were identified (n = 22,248). Hemiarthroplasties for polytrauma, pathologic or open fractures, or patients who had additional surgeries at other body sites during the same stay, as well as those with prior procedures in the same hip, were excluded (21.4% [4768]). Cemented procedures and those with missing or inconsistent implant information (for example, cement used but cementless implant recorded) were further excluded (47.1% [10,485]). To allow for enough events for evaluation, the study sample was restricted to seven stems for which there were at least 300 hemiarthroplasties performed, including four models from DePuy Synthes (Corail®, Summit®, Summit Basic, and Tri-Lock®) and three from Zimmer Biomet (Medial-Lateral [M/L] Taper®, Trabecular Metal®, and Versys® Low Demand Fracture [LD/FX]). The final sample included 5676 cementless hemiarthroplasties: 653 Corail, 402 M/L Taper, 1699 Summit, 1590 Summit Basic, 384 Tri-Lock, 637 Trabecular Metal, and 311 Versys LD/FX. Procedures were performed by 396 surgeons at 35 hospitals. The mean age and BMI for the cohort was 81 years and 24 kg/m 2 , respectively; most were women (66% [3733 of 5676]) and White (79% [4488 of 5676]). Based on standardized mean differences, we controlled for age, race/ethnicity, American Society of Anesthesiologist (ASA) classification, anesthesia technique, operative year, average annual surgeon hemiarthroplasty volume, and operative year across the seven stem groups. Of the 5676 patients, 7% (378 of 5676) were lost to follow-up through membership termination at a median time of 1.6 years, and 56% (3194 of 5676) of the patients died during study follow-up. A multivariable cause-specific Cox proportional hazards regression model was used to evaluate the risk for aseptic revision with adjustment for age, gender, ASA classification, depression, operating surgeon, deficiency anemias, time from admission to surgery, and average annual surgeon hemiarthroplasty volume. A random intercept was included to address effects from hemiarthroplasties performed by the same surgeon. Risk for revision for periprosthetic fracture was also evaluated as a secondary outcome.

resultsIn the adjusted analysis, the Summit Basic (HR 1.91 [95% confidence interval 1.34 to 2.72]; p < 0.001), the M/L Taper (HR 1.91 [95% CI 1.15 to 3.15]; p = 0.01), and the Versys LD/FX (HR 2.12 [95% CI 1.25 to 3.61]; p = 0.005) had higher aseptic revision risks during follow-up when compared with the Summit. No differences were observed for the Corail (HR 0.57 [95% CI 0.29 to 1.10]; p = 0.09), the Tri-Lock (HR 1.13 [95% CI 0.62 to 2.07]; p = 0.68), or the Trabecular Metal (HR 1.14 [95% CI 0.69 to 1.89]; p = 0.61) compared with the Summit. A higher risk for revision because of periprosthetic fracture was observed with the M/L Taper (HR 2.43 [95% CI 1.29 to 4.58]; p = 0.006) and the Summit Basic (within 3 months of follow-up: HR 1.16 [95% CI 0.60 to 2.25]; p = 0.66; after 3 months of follow-up: HR 2.84 [95% CI 1.36 to 5.94]; p = 0.006) stems when compared with the Summit.

conclusionIn a cohort of 5676 cementless hemiarthroplasties, we found differences in revision risks among different femoral stem brands. Based on our findings, we recommend against utilization of the Zimmer M/L Taper, DePuy Summit Basic, and Zimmer Versys LD/FX in the treatment of displaced geriatric femoral neck fractures with cementless hemiarthroplasty. Future large registry studies are needed to further elucidate differences in aseptic revision risk among higher performing cementless femoral stems. Although cemented fixation remains the recommended approach based on the best available evidence in hemiarthroplasty treatment of hip fractures, our findings may help to mitigate aseptic revision risk should cementless fixation be chosen. LEVEL OF EVIDENCE: Level III, therapeutic study.

Indexed as

Arthroplasty, Replacement, HipFemoral Neck FracturesHemiarthroplastyHip ProsthesisPeriprosthetic FracturesProsthesis DesignAgedAged, 80 and overFemaleHumansMaleMiddle AgedRegistriesReoperationRetrospective StudiesTreatment Outcome

Identifiers

PMID39158389
PMCPMC11753737

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked