ArticleAmerican journal of ophthalmology case reports2024
Carbon bursts inside a small aperture intraocular lens after Nd:YAG laser capsulotomy.
Article in American journal of ophthalmology case reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Nd:YAG capsulotomy: an update.Medical hypothesis, discovery & innovation ophthalmology journal · 2026Review
- Review
- Predicted Visual Impact of a Small Aperture Intraocular Lens in Reducing Higher Order Aberrations in Post-Radial Keratotomy Patients.Vision (Basel, Switzerland) · 2025Article
- Surgical implications in intraocular lens exchange with an open posterior capsule: a retrospective case series and review of the literature.Journal of cataract and refractive surgery · 2024Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: The IC-8® Apthera™ (AcuFocus Inc.™, Irvine, California, USA) is the first small aperture intraocular lens (IOL) to receive FDA approval for presbyopia correction in the summer of 2022. It is a single-piece hydrophobic acrylic monofocal lens, which is placed in the capsular bag. In its center it carries a black circular mask (FilterRing™) with a diameter of 3.23 mm consisting of polyvinylidene fluoride and carbon black nanoparticles. In the center of this mask sits a 1.36 mm wide aperture. Thanks to this pinhole effect the IC-8® serves as an extended-depth-of-focus (EDOF) IOL and can be used in presbyopia correction.This report describes the case of a patient with an IC-8® implant who underwent Nd:YAG laser capsulotomy for posterior capsule opacification (PCO). The post laser checkup showed a dark central optical change within the IOL and the patient described optical phenomena as well as blurred central vision, which is why he received IOL exchange. The explanted IC-8® was sent to the Intermountain Ocular Research Center at the University of Utah for further analysis. Observations: A 56-year-old male underwent cataract surgery with implantation of a non-diffractive EDOF-IOL on the right and the IC-8® small aperture IOL on the left eye. On the left eye, the patient had received penetrating keratoplasty seven years prior to the cataract operation due to posttraumatic corneal scarring. The early checkups after cataract surgery showed a corrected distance visual acuity (CDVA) in the left eye of +0.1 logMAR in the first month. About 5 months after the operation, PCO was first described on the left eye leading to a decrease in visual acuity to +0.4 logMAR (CDVA). Due to PCO, Nd:YAG laser capsulotomy was conducted 5 months after the cataract operation on the left eye. 12 shots were applied at 2.7 mJ. The following appointments showed a continuously reduced visual acuity of +1.3 logMAR (uncorrected) on the left eye and the patient described blurry and 'swirled' central vision. By slightly tilting his head and thus not using the center of his optic axis, he would be able to see sharper. Slit lamp examination showed a small optical change inside the IC-8® IOL not resembling a pit but believed to be a small pocket of air. Due to the ongoing symptoms as well as the reduced VA, the seemingly damaged small aperture IOL was exchanged for a three-piece hydrophobic acrylic monofocal lens, which was also placed in the posterior chamber. The explanted IC-8® was sent to the Intermountain Ocular Research Center at the University of Utah for further analysis. Results from gross and light microscopic analysis showed that the change caused by the Nd:YAG laser application consisted of a localized optical area containing carbon black nanoparticles used for the circular mask within the IOL. Conclusions and importance: When dealing with PCO and performing Nd:YAG laser capsulotomy in eyes with an IC-8® IOL implant, the laser shots should be applied either inside the aperture or outside of the black circular mask of the IOL. Otherwise, the Nd:YAG laser can lead to bursts of carbon nanoparticles within the IOL which may cause optical phenomena as well as decreased visual acuity possibly resulting in an IOL exchange.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.