Evidence map›Paper›PMID 39155923›Full record

ArticleIEEE journal of translational engineering in health and medicine2024

A Development of a Sound Recognition-Based Cardiopulmonary Resuscitation Training System.

Dong Hyun Choi, Yoon Ha Joo, Ki Hong Kim, Jeong Ho Park, Hyunjin Joo, Hyoun-Joong Kong, Hyunju Lee, Kyoung Jun Song, Sungwan Kim

Abstract read
In one paragraph

Article in IEEE journal of translational engineering in health and medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Dong Hyun ChoiDepartment of Biomedical EngineeringSeoul National University College of Medicine Jongno Seoul 03080 South Korea.ORCID 0000-0001-6036-1404
Yoon Ha JooBiomedical Research InstituteSeoul National University Hospital Jongno Seoul 03080 South Korea.ORCID 0000-0002-2133-6297
Ki Hong KimDepartment of Emergency MedicineSeoul National University Hospital Jongno Seoul 03080 South Korea.ORCID 0000-0003-2115-0078
Jeong Ho ParkDepartment of Emergency MedicineSeoul National University Hospital Jongno Seoul 03080 South Korea.ORCID 0000-0001-6330-9820
Hyunjin JooInnovative Medical Technology Research InstituteSeoul National University Hospital Jongno Seoul 03080 South Korea.
Hyoun-Joong KongDepartment of Transdisciplinary MedicineInnovative Medical Technology Research InstituteSeoul National University Hospital Jongno Seoul 03080 South Korea.
Hyunju LeeLaboratory of Emergency Medical ServicesBiomedical Research Institute, Seoul National University Hospital Jongno Seoul 03080 South Korea.
Kyoung Jun SongDepartment of Emergency MedicineSeoul Metropolitan Boramae Medical Center Dongjak Seoul 07061 South Korea.
Sungwan KimDepartment of Biomedical EngineeringSeoul National University College of Medicine Jongno Seoul 03080 South Korea.ORCID 0000-0002-9318-849X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The objective of this study was to develop a sound recognition-based cardiopulmonary resuscitation (CPR) training system that is accessible, cost-effective, easy-to-maintain and provides accurate CPR feedback. Beep-CPR, a novel device with accordion squeakers that emit high-pitched sounds during compression, was developed. The sounds emitted by Beep-CPR were recorded using a smartphone, segmented into 2-second audio fragments, and then transformed into spectrograms. A total of 6,065 spectrograms were generated from approximately 40 minutes of audio data, which were then randomly split into training, validation, and test datasets. Each spectrogram was matched with the depth, rate, and release velocity of the compression measured at the same time interval by the ZOLL X Series monitor/defibrillator. Deep learning models utilizing spectrograms as input were trained using transfer learning based on EfficientNet to predict the depth (Depth model), rate (Rate model), and release velocity (Recoil model) of compressions. Results: The mean absolute error (MAE) for the Depth model was 0.30 cm (95% confidence interval [CI]: 0.27-0.33). The MAE of the Rate model was 3.6/min (95% CI: 3.2-3.9). For the Recoil model, the MAE was 2.3 cm/s (95% CI: 2.1-2.5). External validation of the models demonstrated acceptable performance across multiple conditions, including the utilization of a newly-manufactured device, a fatigued device, and evaluation in an environment with altered spatial dimensions. We have developed a novel sound recognition-based CPR training system, that accurately measures compression quality during training. Significance: Beep-CPR is a cost-effective and easy-to-maintain solution that can improve the efficacy of CPR training by facilitating decentralized at-home training with performance feedback.

Indexed as

Cardiopulmonary ResuscitationDeep LearningEquipment DesignHumansSignal Processing, Computer-AssistedSmartphoneSoundSound SpectrographyCardiopulmonary arrestdeep learningfeedback communicationssound recognition

Identifiers

PMID39155923
PMCPMC11329221

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.