Evidence map›Paper›PMID 39155920›Full record

ArticleIEEE journal of translational engineering in health and medicine2024

Non-Contact Measurement of Cardiopulmonary Activity Using Software Defined Radios.

Lei Guan, Xiaodong Yang, Nan Zhao, Malik Muhammad Arslan, Muneeb Ullah, Qurat Ul Ain, Abbas Ali Shah, Akram Alomainy, Qammer H Abbasi

Abstract read
In one paragraph

Article in IEEE journal of translational engineering in health and medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Lei GuanKey Laboratory of High Speed Circuit Design and EMC of Ministry of Education, School of Electronic EngineeringXidian University Xi'an Shaanxi 710071 China.ORCID 0000-0003-1177-3052
Xiaodong YangKey Laboratory of High Speed Circuit Design and EMC of Ministry of Education, School of Electronic EngineeringXidian University Xi'an Shaanxi 710071 China.ORCID 0000-0002-4701-1204
Nan ZhaoKey Laboratory of High Speed Circuit Design and EMC of Ministry of Education, School of Electronic EngineeringXidian University Xi'an Shaanxi 710071 China.ORCID 0000-0002-5353-0158
Malik Muhammad ArslanKey Laboratory of High Speed Circuit Design and EMC of Ministry of Education, School of Electronic EngineeringXidian University Xi'an Shaanxi 710071 China.ORCID 0009-0005-1608-096X
Muneeb UllahKey Laboratory of High Speed Circuit Design and EMC of Ministry of Education, School of Electronic EngineeringXidian University Xi'an Shaanxi 710071 China.
Qurat Ul AinKey Laboratory of High Speed Circuit Design and EMC of Ministry of Education, School of Electronic EngineeringXidian University Xi'an Shaanxi 710071 China.
Abbas Ali ShahKey Laboratory of High Speed Circuit Design and EMC of Ministry of Education, School of Electronic EngineeringXidian University Xi'an Shaanxi 710071 China.
Akram AlomainySchool of Electronic Engineering and Computer ScienceQueen Mary University of London E1 4NS London U.K.ORCID 0000-0002-5802-9194
Qammer H AbbasiJames Watt School of EngineeringUniversity of Glasgow G12 8QQ Glasgow U.K.ORCID 0000-0002-7097-9969

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Vital signs are important indicators to evaluate the health status of patients. Channel state information (CSI) can sense the displacement of the chest wall caused by cardiorespiratory activity in a non-contact manner. Due to the influence of clutter, DC components, and respiratory harmonics, it is difficult to detect reliable heartbeat signals. To address this problem, this paper proposes a robust and novel method for simultaneously extracting breath and heartbeat signals using software defined radios (SDR). Specifically, we model and analyze the signal and propose singular value decomposition (SVD)-based clutter suppression method to enhance the vital sign signals. The DC is estimated and compensated by the circle fitting method. Then, the heartbeat signal and respiratory signal are obtained by the modified variational modal decomposition (VMD). The experimental results demonstrate that the proposed method can accurately separate the respiratory signal and the heartbeat signal from the filtered signal. The Bland-Altman analysis shows that the proposed system is in good agreement with the medical sensors. In addition, the proposed system can accurately measure the heart rate variability (HRV) within 0.5m. In summary, our system can be used as a preferred contactless alternative to traditional contact medical sensors, which can provide advanced patient-centered healthcare solutions.

Indexed as

Heart RateSignal Processing, Computer-AssistedSoftwareAdultAlgorithmsFemaleHumansMaleMonitoring, PhysiologicRespirationYoung Adultheartbeat estimationOFDMSVDVMD

Identifiers

PMID39155920
PMCPMC11329224

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.