ArticleScientific reports2024
Ultra-sensitive optimized one-dimensional phononic crystal as a fluidic sensor to enhance the measurement of acetic acid concentration.
Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Article
- Detection of Spoilage-Associated Acetic Acid Levels Using a Transcription-Based Whole-Cell Biosensor.Microbial biotechnology · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The current investigation theoretically presents a one-dimensional phononic crystal (PnC) as a fluidic sensor. The sensor under consideration aims to distinguish the concentration of acetic acid. The primary configuration of the proposed sensor is constructed with lead, epoxy, and a defect layer in the middle of the structure, that is filled with acetic acid (vinegar). As a result of the rise in density and decline in the speed of sound at a 100% concentration of acetic acid in comparison to pure water, the peak frequency of the output has shifted towards lower frequencies. Given that the maximum permissible concentration of acetic acid in water for vinegar is above 30%, sensor simulations were conducted within the concentration range of 25-35% with a step size of 1%. Interestingly, the sensitivity of the sensor exhibits a polynomial change in response to the concentration of acetic acid. Consequently, the highest level of sensitivity, which corresponds to the lowest concentration of vinegar, is recorded as 48.44 × 10
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.