Evidence map›Paper›PMID 39153755›Full record

Observational studyBMJ open ophthalmology2024

Factors influencing the reliability of measurements in eyes with full-thickness macular holes: are we measuring incorrectly?

George Moussa, Assad Jalil, Myrta Lippera, Nouf Alnafisee, Tsveta Ivanova

Abstract readObservational Study
In one paragraph

Observational study in BMJ open ophthalmology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

George MoussaAcademic Unit of Ophthalmology, University of Birmingham College of Medical and Dental Sciences, Birmingham, UK.ORCID 0000-0002-5136-6841
Assad JalilManchester Royal Eye Hospital, Manchester, UK.
Myrta LipperaManchester Royal Eye Hospital, Manchester, UK.ORCID 0000-0002-5027-3483
Nouf AlnafiseeManchester Royal Eye Hospital, Manchester, UK.
Tsveta IvanovaManchester Royal Eye Hospital, Manchester, UK tsvetaivanova14@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe calliper function is used for manual measurements of full thickness macular holes (FTMHs). We aimed to investigate whether a reproducible difference could be detected beyond interobserver variability between two commonly used manufacturers in their manual calliper facility in spectral domain optical coherence tomography (OCT) for metrics related to FTMH.

methodsThis is a non-interventional, retrospective, observational study. Two independent observers examined 8 eyes (16 OCT) scans and 128 measurements (minimal linear diameter (MLD), basal diameter and hole height on both sides) of FTMHs, taken on Heidelberg Spectralis and Topcon Triton (OCT machines). The interobserver agreement and OCT machine agreement of measurements were analysed by Bland-Altman plots and intraclass correlation coefficient (ICC) analysis. Spectralis and Triton had 125 µm and 50 µm horizontal b-scan spacing, respectively.

resultsOverall, we report high absolute agreement in interobserver (ICC 0.991 (95% CI 0.985 to 0.995, p<0.001)) and OCT machine (ICC 0.993 (95% CI 0.987 to 0.996, p<0.001)) variability. Lower horizontal resolution in Triton compared with Spectralis leads to interobserver variability, in smaller horizontal measurements. Lower horizontal scanning density in Spectralis lead to relatively large interobserver variation if different reference scans were chosen, and consistently smaller MLD measurements than Triton. Vertical measurements without 1:1 scaling lead to inaccurate exaggerated oblique vertical measurements. Calliper function appears otherwise identically calibrated.

conclusionsWe report excellent interobserver and OCT machine agreement in measurements. However, the paper shows several factors that could influence the reliability of measurements acquired in eyes with FTMHs, such as the dimension of the hole as well as different image resolution, density scanning protocols or vertical scaling of the OCT machines viewing platform.

Indexed as

Observer VariationRetinal PerforationsTomography, Optical CoherenceAgedFemaleHumansMaleMiddle AgedReproducibility of ResultsRetrospective StudiesImagingMaculaRetina

Identifiers

PMID39153755
PMCPMC11331849

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.