Evidence map›Paper›PMID 39152500›Full record

Observational studyJournal of orthopaedic surgery and research2024

A novel robotic surgical assistant for total knee arthroplasty has a learning curve ranging from 6 to 14 cases and exhibits high accuracy in tibial bone cuts.

Nimit Thongpulsawad, Chaiwat Achawakulthep, Tawan Intiyanaravut

Abstract readObservational Study
In one paragraph

Observational study in Journal of orthopaedic surgery and research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Review
  5. Observational
  6. Review
  7. Review
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Nimit ThongpulsawadDepartment of Orthopedic Surgery, Golden Jubilee Medical Center, Faculty of Medicine Siriraj Hospital, Mahidol University, Nakhon Pathom, Thailand.
Chaiwat AchawakulthepDepartment of Orthopedic Surgery, Golden Jubilee Medical Center, Faculty of Medicine Siriraj Hospital, Mahidol University, Nakhon Pathom, Thailand.
Tawan IntiyanaravutDepartment of Orthopedic Surgery, Golden Jubilee Medical Center, Faculty of Medicine Siriraj Hospital, Mahidol University, Nakhon Pathom, Thailand. tawan.int@mahidol.ac.th.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe adoption of robot-assisted total knee arthroplasty (TKA) aims to enhance the precision of implant positioning and limb alignment. Despite its benefits, the adoption of such technology is often accompanied by an initial learning curve, which may result in increased operative times. This study sought to determine the learning curve for the ROSA (Robotic Surgical Assistant) Knee System (Zimmer Biomet) in performing TKA and to evaluate the accuracy of the system in executing bone cuts and angles as planned. The hypothesis of this study was that cumulative experience with this robotic system would lead to reduced operative times. Additionally, the ROSA system demonstrated reliability in terms of the accuracy and reproducibility of bone cuts.

methodsIn this retrospective observational study, we examined 110 medical records from 95 patients who underwent ROSA-assisted TKA performed by three surgeons. We employed the cumulative summation methodology to assess the learning curves related to operative time. Furthermore, we evaluated the accuracy of the ROSA Knee System in performing TKA by comparing planned versus validated values for femoral and tibial bone cuts and angles.

resultsThe learning curve for the ROSA Knee System spanned 14, 14, and 6 cases for the respective surgeons, with operative times decreasing by 22 min upon reaching proficiency (70.8 vs. 48.9 min; p < 0.001). Significant discrepancies were observed between the average planned and validated cuts and angles for femoral bone cuts (0.4 degree ± 2.4 for femoral flexion, 0.1 degree ± 0.6 for femoral coronal alignment, 0.3 mm ± 1.2 for distal medial femoral resection, 1.4 mm ± 8.8 for distal lateral femoral resection) and hip-knee-ankle axis alignment (0.3 degree ± 1.9 )(p < 0.05) but not for tibial bone cuts. Differences between planned and validated measurements during the learning and proficiency phases were nonsignificant across all parameters, except for the femoral flexion angle (0.42 degree ± 0.8 vs. 0.44 degree ± 2.7) (p = 0.49).

conclusionThe ROSA Knee System can be integrated into surgical workflows after a modest learning curve of 6 to 14 cases. The system demonstrated high accuracy and reproducibility, particularly for tibial bone cuts. Acknowledging the learning curve associated with new robot-assisted TKA technologies is vital for their effective implementation.

Indexed as

Arthroplasty, Replacement, KneeLearning CurveRobotic Surgical ProceduresTibiaAgedAged, 80 and overFemaleHumansMaleMiddle AgedOperative TimeReproducibility of ResultsRetrospective StudiesAccuracyCumulative summation analysisLearning curveOperative timeRobot-assisted systemROSA knee systemTotal knee arthroplasty