Evidence map›Paper›PMID 39150966›Full record

ArticlePloS one2024

Clinical validation of enhanced CT imaging for distal radius fractures through conditional Generative Adversarial Networks (cGAN).

Hyojune Kim, Seung Min Ryu, Ji-Soo Keum, Sang-Il Oh, Kyung-Nam Kim, Young Ho Shin, In-Ho Jeon, Kyoung Hwan Koh

Abstract readValidation Study
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Hyojune KimDepartment of Orthopedic Surgery, Hospital of Chung-Ang University of Medicine, Dongjak-gu, Seoul, Republic of Korea.
Seung Min RyuDepartment of Orthopedic Surgery, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea.
Ji-Soo KeumWaycen Inc., Seoul, Republic of Korea.
Sang-Il OhWaycen Inc., Seoul, Republic of Korea.
Kyung-Nam KimWaycen Inc., Seoul, Republic of Korea.
Young Ho ShinDepartment of Orthopedic Surgery, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea.
In-Ho JeonDepartment of Orthopedic Surgery, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea.
Kyoung Hwan KohDepartment of Orthopedic Surgery, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea.ORCID 0000-0002-6181-9621

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background/purposeDistal radius fractures (DRFs) account for approximately 18% of fractures in patients 65 years and older. While plain radiographs are standard, the value of high-resolution computed tomography (CT) for detailed imaging crucial for diagnosis, prognosis, and intervention planning, and increasingly recognized. High-definition 3D reconstructions from CT scans are vital for applications like 3D printing in orthopedics and for the utility of mobile C-arm CT in orthopedic diagnostics. However, concerns over radiation exposure and suboptimal image resolution from some devices necessitate the exploration of advanced computational techniques for refining CT imaging without compromising safety. Therefore, this study aims to utilize conditional Generative Adversarial Networks (cGAN) to improve the resolution of 3 mm CT images (CT enhancement).

methodsFollowing institutional review board approval, 3 mm-1 mm paired CT data from 11 patients with DRFs were collected. cGAN was used to improve the resolution of 3 mm CT images to match that of 1 mm images (CT enhancement). Two distinct methods were employed for training and generating CT images. In Method 1, a 3 mm CT raw image was used as input with the aim of generating a 1 mm CT raw image. Method 2 was designed to emphasize the difference value between the 3 mm and 1 mm images; using a 3 mm CT raw image as input, it produced the difference in image values between the 3 mm and 1 mm CT scans. Both quantitative metrics, such as peak signal-to-noise ratio (PSNR), mean squared error (MSE), and structural similarity index (SSIM), and qualitative assessments by two orthopedic surgeons were used to evaluate image quality by assessing the grade (1~4, which low number means high quality of resolution).

resultsQuantitative evaluations showed that our proposed techniques, particularly emphasizing the difference value in Method 2, consistently outperformed traditional approaches in achieving higher image resolution. In qualitative evaluation by two clinicians, images from method 2 showed better quality of images (grade: method 1, 2.7; method 2, 2.2). And more choice was found in method 2 for similar image with 1 mm slice image (15 vs 7, p = 201).

conclusionIn our study utilizing cGAN for enhancing CT imaging resolution, the authors found that the method, which focuses on the difference value between 3 mm and 1 mm images (Method 2), consistently outperformed.

Indexed as

Radius FracturesTomography, X-Ray ComputedWrist FracturesHumansNeural Networks, Computer

Identifiers

PMID39150966
PMCPMC11329132

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.