ArticleMikrochimica acta2024
2D/1D VSe
Article in Mikrochimica acta, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Nickel-Based Nanoparticles Synthesized by Pulsed Laser Ablation in Liquid with Multiphase Structure for Electrochemical Dopamine Sensing.ACS omega · 2026Article
- A novel nail polish/graphite/nickel nanoparticles-based disposable screen-printed sensor for enhanced voltammetric detection of mefenamic acid in environmental water samples.Mikrochimica acta · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
For the first time the sensitive determination of carbendatim (CRB) is reported utilizing a well-designed sensing architecture based on vanadium diselenide-multiwalled carbon nanotube (VSMC). FTIR, XRD, FESEM, EDS, and EIS were employed to evaluate the sensor's structural integrity, and the results demonstrated the successful integration of nanomaterials, resulting in a robust and sensitive electrochemical sensor. Cyclic voltammetry (CV) and chronoamperometric (CA) investigations showed that the sensor best performed at pH 8.0 (BRB) with an excellent detection limit of 9.80 nM with a wide linear range of 0.1 to 10.0 µM. A more thermodynamically viable oxidation of CRB was observed at the VSMC/GCE, with a shift of 200 mV in peak potential towards the less positive side compared with the unmodified GCE. In addition, the sensor demonstrated facile heterogeneous electron transfer, favorable anti-fouling traits in the presence of a wide range of interferents, good stability, and reproducible analytical performance. Finally, the developed sensor was validated for real-time quantification of CRB from spiked water, food, and bio-samples, which depicted acceptable recoveries (98.6 to 101.5%) with RSD values between 0.35 and 2.23%. Further, to derive the possible sensing mechanism, the valence orbitals projected density of states (PDOS) for C, H, and N atoms of an isolated CRB molecule, VSe
Indexed as
Identifiers
39150580What OpenQuestion holds
Registered trials