Evidence map›Paper›PMID 39150276›Full record

ArticleJournal of clinical microbiology2024

Evaluation of a point-of-care rapid HIV antibody test with insights into acute HIV symptomatology in a population with low prevalence.

Tina I Bui, Christopher W Farnsworth, Neil W Anderson

Abstract readEvaluation Study
In one paragraph

Article in Journal of clinical microbiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Tina I BuiDepartment of Pathology & Immunology, Washington University School of Medicine in St. Louis, Saint Louis, Missouri, USA.ORCID 0000-0002-4110-3263
Christopher W FarnsworthDepartment of Pathology & Immunology, Washington University School of Medicine in St. Louis, Saint Louis, Missouri, USA.ORCID 0000-0001-7169-3850
Neil W AndersonDepartment of Pathology, University Hospitals Health System, Cleveland, Ohio, USA.ORCID 0000-0002-2805-2174

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Many emergency departments (ED) use rapid human immunodeficiency virus (HIV) antibody tests as screening tools, despite limited sensitivity for detecting acute HIV infections. In a 4-year retrospective analysis of 1,192 patients, we evaluated the performance of a third-generation rapid HIV antibody assay tested at point-of-care (POC, Chembio Sure Check HIV 1/2) against in-lab fourth-generation screening (Abbott Architect Ag/Ab Combo). Compared to complete algorithmic testing, the POC test demonstrated a 92.5% sensitivity (95% CI = 84.6-96.5), 98.1% specificity (95% CI = 97.1-98.8), 99.5% negative predictive value (NPV; 95% CI = 98.8-99.8), and a 77.9% positive predictive value (PPV; 95% CI = 68.6-85.1). Notably, the POC test failed to detect 100% (3/3) of acute HIV infections (defined as Fiebig stage 2) and 3.8% (2/52) established HIV infections, where viral loads were 5.9, 6.7, and >7 log

Indexed as

HIV AntibodiesHIV InfectionsPoint-of-Care SystemsSensitivity and SpecificityAdolescentAdultAgedEmergency Service, HospitalFemaleHIV TestingHumansMaleMiddle AgedPoint-of-Care TestingPredictive Value of TestsPrevalenceHIV Antibodiesacute HIVHIVpoint-of-carerapid testing

Identifiers

PMID39150276
PMCPMC11389137

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.