Evidence map›Paper›PMID 39149507›Full record

ArticleResearch square2024

Dynamic X-ray Microtomography vs. Laser-Doppler Vibrometry: A Comparative Study.

Aleksandra Ivanovic, Jeffrey Tao Cheng, Margaux Schmeltz, Christian M Schlepütz, Anne Bonnin, Lukas Anschuetz

Abstract readPreprint
In one paragraph

Article in Research square, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Aleksandra IvanovicDepartment of Otorhinolaryngology, Head and Neck Surgery, Inselspital, Bern University Hospital, University of Bern, Switzerland, 2Hearing Research Laboratory, ARTORG Center for Biomedical Engineering Research, University of Bern, Switzerland, Paul Scherrer Institut, Swiss Light Source, Villigen PSI, Switzerland.ORCID 0000-0002-1322-3794
Jeffrey Tao ChengDepartment of Otolaryngology, Head and Neck Surgery, Mass. Eye and Ear, Boston Children Hospital, Harvard Medical School, Boston, 02114, MA, USA.ORCID 0000-0003-3674-7301
Margaux SchmeltzSwiss Light Source, Paul Scherrer Institut, Villigen PSI, Switzerland.ORCID 0000-0002-0286-7850
Christian M SchlepützSwiss Light Source, Paul Scherrer Institut, Villigen PSI, Switzerland.ORCID 0000-0002-0485-2708
Anne BonninSwiss Light Source, Paul Scherrer Institut, Villigen PSI, Switzerland.ORCID 0000-0001-5537-8682
Lukas AnschuetzDepartment of Otorhinolaryngology, Head and Neck Surgery, CHUV Centre Hospitalier Universitaire Vaudois and University of Lausanne, Lausanne, Switzerland.ORCID 0000-0001-6927-0664

Funding

Middle Ear Nonlinearity in High Intensity Sound: Impact on Hearing Damage and ProtectionR01DC016079 · NIDCD · MASSACHUSETTS EYE AND EAR INFIRMARY · PI Jeffrey Tao Cheng · 2017 to 2026
$4.1M
NIDCD NIH HHS R01 DC016079
6 · The paper itself

Abstract

Purpose: There are challenges in understanding the biomechanics of the human middle ear, and established methods for studying this system show significant limitations. In this study, we evaluate a novel dynamic imaging technique based on synchrotron X-ray microtomography designed to assess the biomechanical properties of the human middle ear by comparing it to laser-Doppler vibrometry (LDV). Methods: We examined three fresh-frozen temporal bones (TB) using dynamic synchrotron-based X-ray microtomography for 256 Hz and 512 Hz, stimulated at 110 dB and 120 dB SPL. In addition, we performed measurements on these TBs using 1D LDV, a well-established method. Results: The normalized displacement values (μm/Pa) at the umbo and the posterior crus of the stapes are consistent or within 5-10 dB differences between all LDV and dynamic microtomography measurements and previously reported literature references. In general, the overall behavior is similar between the two measurement techniques. Conclusion: In conclusion, our results demonstrate the suitability of dynamic synchrotron-based X-ray microtomography in studying the middle ear's biomechanics. However, this study shows that better standardization regarding acoustic stimulation and measurement points is needed to better compare the two measurement techniques.

Indexed as

dynamic synchrotron-based X-ray microtomographylaser-Doppler vibrometryMiddle earphase-contrast

Identifiers

PMID39149507
PMCPMC11326387

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.