Evidence map›Paper›PMID 39148312›Full record

ArticleLab on a chip2024

Roll-to-roll manufacturing of large surface area PDMS devices, and application to a microfluidic artificial lung.

Andrew Zhang, Kartik Tharwani, Jennifer Wang, Gabriele K Seilo, Michael A Atie, Joseph A Potkay

Abstract read
In one paragraph

Article in Lab on a chip, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Andrew ZhangECLS Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA. jpotkay@umich.edu.ORCID 0000-0001-8983-2126
Kartik TharwaniECLS Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA. jpotkay@umich.edu.
Jennifer WangECLS Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA. jpotkay@umich.edu.
Gabriele K SeiloECLS Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA. jpotkay@umich.edu.ORCID 0009-0003-9804-6292
Michael A AtieECLS Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA. jpotkay@umich.edu.
Joseph A PotkayECLS Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA. jpotkay@umich.edu.ORCID 0000-0003-0320-7130

Funding

Human-scale microfluidic artificial lungR01HL144660 · NHLBI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI POTKAY, JOSEPH ALLEN · 2019 to 2022
$2.6M
CTSA Predoctoral T32 at the University of MichiganT32TR004371 · NCATS · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI VICKI L ELLINGROD, MICHAEL Allan HOLINSTAT · 2023 to 2026
$2.2M
NCATS NIH HHS T32 TR004371NHLBI NIH HHS R01 HL144660
6 · The paper itself

Abstract

The ability to cost-effectively produce large surface area microfluidic devices would bring many small-scale technologies such as microfluidic artificial lungs (μALs) from the realm of research to clinical and commercial applications. However, efforts to scale up these devices, such as by stacking multiple flat μALs have been labor intensive and resulted in bulky devices. Here, we report an automated manufacturing system, and a series of cylindrical multi-layer lungs manufactured with the system and tested for fluidic fidelity and function. A roll-to-roll (R2R) system to engrave multiple-layer devices was assembled. Unlike typical applications of R2R, the rolling process is synchronized to achieve consistent radial positioning. This allows the fluidics in the final device to be accessed without being unwrapped. To demonstrate the capabilities of the R2R manufacturing system, this method was used to manufacture multi-layer μALs. Gas and blood are engraved in alternating layers and routed orthogonally to each other. The proximity of gas and blood separated by gas permeable PDMS permits CO

Indexed as

Artificial OrgansDimethylpolysiloxanesLab-On-A-Chip DevicesLungAnimalsEquipment DesignMicrofluidic Analytical TechniquesSurface PropertiesbaysilonDimethylpolysiloxanes

Identifiers

PMID39148312
PMCPMC11327552

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.