Evidence map›Paper›PMID 39147821›Full record

ArticleScientific reports2024

Two-screw osteosynthesis is biomechanically superior to single-screw osteosynthesis for type II odontoid fractures.

Paul Jonathan Roch, Elisa Salge, Miguel Angel Bravo Cabrera, Friederike Sophie Klockner, Marc-Pascal Meier, Katharina Jäckle, Wolfgang Lehmann, Lukas Weiser

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Paul Jonathan RochDepartment of Trauma Surgery, Orthopaedics and Plastic Surgery, University of Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany. jonathan.roch@med.uni-goettingen.de.
Elisa SalgeDepartment of Trauma Surgery, Orthopaedics and Plastic Surgery, University of Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany.
Miguel Angel Bravo CabreraDepartment of Trauma Surgery, Orthopaedics and Plastic Surgery, University of Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany.
Friederike Sophie KlocknerDepartment of Trauma Surgery, Orthopaedics and Plastic Surgery, University of Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany.
Marc-Pascal MeierDepartment of Trauma Surgery, Orthopaedics and Plastic Surgery, University of Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany.
Katharina JäckleDepartment of Trauma Surgery, Orthopaedics and Plastic Surgery, University of Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany.
Wolfgang LehmannDepartment of Trauma Surgery, Orthopaedics and Plastic Surgery, University of Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany.
Lukas WeiserDepartment of Trauma Surgery, Orthopaedics and Plastic Surgery, University of Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The data on the use of a one- or two-screw technique (1S, 2S) for ventral osteosynthesis of type II dens fractures are contradictory. The aim was to design an apparatus to mimic the physiological conditions and test stability with 1S, 2S, and a headless compression screw (HCS) for osteosynthesis of artificially created type II odontoid fractures. The apparatus was mounted on a Zwick materials testing machine. A total of 18 C1-2 specimens were stratified into three groups (1S, 2S, HCS). Odontoid fractures were artificially created, and osteosynthesis was performed. Each specimen was tested at loads increasing from 1 to 40 N. Screw loosening was observed visually, by fatigue data, and by a camera tracking system. Analysis of the Zwick data and the camera data revealed a significant higher stability after 2S compared to 1S and HCS treatment (Zwick data: p = 0.021, camera data: p < 0.001), while visible screw loosening showed a superiority of the 2S only over HCS (p = 0.038). The developed apparatus allowed the dynamic study of the atlantoaxial joint with a high approximation to physiological conditions. The results demonstrated superiority of the 2S over the 1S and HCS in biomechanical stability in the treatment of type II odontoid fractures.

Indexed as

Bone ScrewsFracture Fixation, InternalOdontoid ProcessSpinal FracturesBiomechanical PhenomenaHumansAnterior approachBiomechanicalOdontoid fractureOne screwOsteosynthesis odontoidTwo screws

Identifiers

PMID39147821
PMCPMC11327284

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.