ArticleNature communications2024
Neutral beam microscopy with a reciprocal space approach using magnetic beam spin encoding.
Article in Nature communications, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Overcoming velocity broadening effects in magnetic beam encoded microscopy: a wavelength-resolved imaging scheme.Royal Society open science · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
The emerging technique of neutral beam microscopy offers a non-perturbative way of imaging surfaces of various materials which cannot be studied using conventional microscopes. Current neutral beam microscopes use either diffractive focusing or pin-hole scanning to achieve spatial resolution, and are characterised by a strong dependence of the imaging time on the required resolution. In this work we introduce an alternative method for achieving spatial resolution with neutral atom beams which is based on manipulating the magnetic moments of the beam particles in a gradient field, and is characterised by a much weaker dependence of the imaging time on the image resolution. The validity of the imaging approach is demonstrated experimentally by reconstructing one dimensional profiles of the beam which are in good agreement with numerical simulation calculations. Numerical simulations are used to demonstrate the dependence of the signal to noise on the scan resolution and the topography of the sample, and assess the broadening effect due to the spread of velocities of the beam particles. The route towards implementing magnetic encoding in high resolution microscopes is discussed.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.