Evidence map›Paper›PMID 39145278›Full record

ArticleFrontiers in cardiovascular medicine2024

Transesophageal echocardiography guidance for percutaneous closure of PFO and a new method to improve the diagnosis and safety during the procedures.

Limin Luo, Zehan Xie, Qiaoyan Wu, Qiang Liu, Huiping Hou, Yongshi Wang, Xianhong Shu

Abstract read
In one paragraph

Article in Frontiers in cardiovascular medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Limin LuoDepartment of Echocardiography, Zhongshan Hospital (Xiamen), Fudan University, Xiamen, Fujian, China.
Zehan XieDepartment of Echocardiography, Zhongshan Hospital (Xiamen), Fudan University, Xiamen, Fujian, China.
Qiaoyan WuDepartment of Echocardiography, Zhongshan Hospital (Xiamen), Fudan University, Xiamen, Fujian, China.
Qiang LiuDepartment of Echocardiography, Zhongshan Hospital (Xiamen), Fudan University, Xiamen, Fujian, China.
Huiping HouDepartment of Echocardiography, Zhongshan Hospital (Xiamen), Fudan University, Xiamen, Fujian, China.
Yongshi WangDepartment of Echocardiography, Zhongshan Hospital (Xiamen), Fudan University, Xiamen, Fujian, China.
Xianhong ShuDepartment of Echocardiography, Zhongshan Hospital (Xiamen), Fudan University, Xiamen, Fujian, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Percutaneous patent foramen ovale (PFO) closure is becoming more and more common for the treatment or prevention of PFO-associated right-to-left shunt (RLS). This study aims to investigate the value of transesophageal echocardiography (TEE) in percutaneous PFO closure, and to explore a new method that can improve intraoperative diagnosis and surgical safety. Materials and methods: Based on our inclusion and exclusion criteria, we enrolled 73 patients between 16 and 70 years old (average age 43.25 ± 14.87 years) who underwent percutaneous PFO closure at the Department of Cardiac Surgery, Zhongshan Hospital (Xiamen), Fudan University, from January 2022 to December 2023. Out of the 73 enrolled patients, there were 28 males (38.36%) and 45 females (61.64%), 29 migraine patients (39.73%), 14 patients (19.19%) with headache and dizziness, 14 patients (19.18%) with a history of cerebral infarction (CI), and 25 patients (34.25%) with CI, lacunar infarction or ischemic focus on magnetic resonance imaging (MRI). All patients received routine transthoracic echocardiography (TTE) and agitated saline contrast echocardiography (ASCE) before operations. Percutaneous closure of PFO was completed under the guidance of TEE. In 12 patients, the method of "injection of heparinized sterile saline through the delivery sheath" was used to observe their RLS, and the anatomical characteristics of the PFO according to the shunt path were monitored and evaluated. This method was also applied to some patients to guide the conveyor to pass through the foramen ovale (FO) channel safely and effectively, thereby improving the success rate of PFO closure. Results: The application of TEE during the procedure of percutaneous PFO closure, including preoperative evaluation, intraoperative guidance, and postoperative reevaluation, can offer further details about the anatomical and shunt characteristics of PFO, improve the diagnosis rate, and confirm the safety of the surgical path. It ensures the safety and reliability of the whole operation, greatly improving the success rate and reducing postoperative complications. Conclusions: TEE guidance of percutaneous PFO closure has the advantages of minimal trauma, no radiation and real-time visualization, while injecting heparinized sterile saline through the delivery sheath is safer and more effective in improving the success rate and reducing postoperative complications.

Indexed as

cerebral infarction (CI)cryptogenic strokecryptogenic stroke (CS)echocardiographymigraine atrial septal defectpercutaneous PFO closurePFOtransesophageal echocardiography

Identifiers

PMID39145278
PMCPMC11321958

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.