Evidence map›Paper›PMID 39144040›Full record

ArticleQuantitative imaging in medicine and surgery2024

Experimental glaucoma microstent implantation in two animal models and human donor eyes-an

Jens Runge, Sabine Kischkel, Jonas Keiler, Niels Grabow, Klaus-Peter Schmitz, Stefan Siewert, Andreas Wree, Rudolf F Guthoff, Thomas Stahnke

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jens RungeDepartment of Ophthalmology, Rostock University Medical Center, Rostock, Germany.ORCID https://orcid.org/0000-0002-6883-7961
Sabine KischkelInstitute of Biomedical Engineering, Rostock University Medical Center, Rostock, Germany.ORCID https://orcid.org/0000-0002-5018-3920
Jonas KeilerInstitute of Anatomy, Rostock University Medical Center, Rostock, Germany.ORCID https://orcid.org/0000-0003-0893-3254
Niels GrabowInstitute of Biomedical Engineering, Rostock University Medical Center, Rostock, Germany.
Klaus-Peter SchmitzInstitute of Biomedical Engineering, Rostock University Medical Center, Rostock, Germany.
Stefan SiewertInstitute for Implant Technology and Biomaterials e.V., Rostock-Warnemünde, Germany.ORCID https://orcid.org/0000-0002-8139-0471
Andreas WreeInstitute of Anatomy, Rostock University Medical Center, Rostock, Germany.
Rudolf F GuthoffDepartment of Ophthalmology, Rostock University Medical Center, Rostock, Germany.
Thomas StahnkeDepartment of Ophthalmology, Rostock University Medical Center, Rostock, Germany.ORCID https://orcid.org/0000-0003-2425-7268

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Minimally invasive glaucoma surgery (MIGS) has become an important treatment approach for primary open angle glaucoma. Restoration of aqueous humour drainage by means of alloplastic implants represents a promising treatment option and is itself subject of methodological development. An adequate positioning in the targeted tissue regions is essential is important for the performance of our in-house developed Rostock glaucoma microstent (RGM). The aim of this study was to evaluate the applicability of two animal models and human donor eyes regarding RGM placement. Methods: Eyes were obtained from rabbits, pigs, and human body donations. After orbital exenterations, RGMs were placed in the anterior chamber draining in the subconjunctival space. X-ray contrast was increased by incubation in aqueous iodine solution for subsequent detailed micro-computed tomography (micro-CT)-based visualization and analysis. Results: In contrast to the human and porcine eyes, the stent extended far to the posterior pole with a more pronounced curvature along the globe in the rabbit eyes due to their smaller size. However, dysfunctional deformations were not depicted. Adequate positioning of the stent's inflow area in the anterior chamber and the outflow area in the Tenon space was achieved in both the animal models and the human eye. Conclusions: Micro-CT has proven to be a valuable tool for postoperative

Indexed as

3Rs principleAlloplastic implantmicro-computed tomography (micro-CT)minimally invasive glaucoma surgery (MIGS)Rostock glaucoma microstent (RGM)

Identifiers

PMID39144040
PMCPMC11320535

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.