Evidence map›Paper›PMID 39143991›Full record

ArticleQuantitative imaging in medicine and surgery2024

Automatic measurement of anatomical parameters of the lumbar vertebral body and the intervertebral disc on radiographs by deep learning.

Hongyan Yao, Zhihong Zhang, Guohua Cheng, Xiaofei Chen, Linyang He, Wenqi Wang, Sheng Zhou, Ping Wang

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Hongyan YaoDepartment of Radiology, Gansu Provincial Hospital, Lanzhou, China.
Zhihong ZhangThe First Clinical Medical College of Gansu University of Chinese Medicine, Lanzhou, China.
Guohua ChengHangzhou Jianpei Technology Co., Ltd., Hangzhou, China.
Xiaofei ChenDepartment of Radiology, Gansu Provincial Hospital of Traditional Chinese Medicine, Lanzhou, China.
Linyang HeHangzhou Jianpei Technology Co., Ltd., Hangzhou, China.
Wenqi WangDepartment of Radiology, Gansu Provincial Hospital of Traditional Chinese Medicine, Lanzhou, China.
Sheng ZhouDepartment of Radiology, Gansu Provincial Hospital, Lanzhou, China.
Ping WangDepartment of Radiology, Gansu Provincial Hospital, Lanzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Lumbar spine disorders are one of the common causes of low back pain (LBP). Objective and reliable measurement of anatomical parameters of the lumbar spine is essential in the clinical diagnosis and evaluation of lumbar disorders. However, manual measurements are time-consuming and laborious, with poor consistency and repeatability. Here, we aim to develop and evaluate an automatic measurement model for measuring the anatomical parameters of the vertebral body and intervertebral disc based on lateral lumbar radiographs and deep learning (DL). Methods: A model based on DL was developed with a dataset consisting of 1,318 lateral lumbar radiographs for the prediction of anatomical parameters, including vertebral body heights (VBH), intervertebral disc heights (IDH), and intervertebral disc angles (IDA). The mean of the values obtained by 3 radiologists was used as a reference standard. Statistical analysis was performed in terms of standard deviation (SD), mean absolute error (MAE), Percentage of correct keypoints (PCK), intraclass correlation coefficient (ICC), regression analysis, and Bland-Altman plot to evaluate the performance of the model compared with the reference standard. Results: The percentage of intra-observer landmark distance within the 3 mm threshold was 96%. The percentage of inter-observer landmark distance within the 3 mm threshold was 94% (R1 and R2), 92% (R1 and R3), and 93% (R2 and R3), respectively. The PCK of the model within the 3 mm distance threshold was 94-99%. The model-predicted values were 30.22±3.01 mm, 10.40±3.91 mm, and 10.63°±4.74° for VBH, IDH, and IDA, respectively. There were good correlation and consistency in anatomical parameters of the lumbar vertebral body and disc between the model and the reference standard in most cases (R Conclusions: The newly proposed model based on a DL algorithm can accurately measure various anatomical parameters on lateral lumbar radiographs. This could provide an accurate and efficient measurement tool for the quantitative evaluation of spinal disorders.

Indexed as

anatomical parametersautomatic measurementDeep learning (DL)lateral lumbar radiograph

Identifiers

PMID39143991
PMCPMC11320507

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.