Evidence map›Paper›PMID 39143348›Full record

ArticleEuropean journal of pediatrics2024

Rapid complete blood count and C-reactive protein determination with the Horiba Microsemi analyzer: the experience in neonatal intensive care unit of Careggi University Hospital.

Francesca Nencini, Alessandro Bonari, Francesca Romano, Sara Ciullini Mannurita, Alessandra Mongia, Maria Garieri, Carlo Dani, Orazio Manzo, Maria Pontieri, Alessandra Fanelli

Abstract readComparative Study
In one paragraph

Article in European journal of pediatrics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Francesca Nencini *General Laboratory, Careggi University Hospital, Florence, Italy.
Alessandro Bonari *General Laboratory, Careggi University Hospital, Florence, Italy.
Francesca RomanoGeneral Laboratory, Careggi University Hospital, Florence, Italy.
Sara Ciullini MannuritaGeneral Laboratory, Careggi University Hospital, Florence, Italy.
Alessandra MongiaGeneral Laboratory, Careggi University Hospital, Florence, Italy.
Maria GarieriDivision of Neonatology and Neonatal Intensive Care Unit, Careggi University Hospital, Florence, Italy.
Carlo DaniDivision of Neonatology and Neonatal Intensive Care Unit, Careggi University Hospital, Florence, Italy. carlo.dani@unifi.it.
Orazio ManzoGeneral Laboratory, Careggi University Hospital, Florence, Italy.
Maria PontieriGeneral Laboratory, Careggi University Hospital, Florence, Italy.
Alessandra FanelliGeneral Laboratory, Careggi University Hospital, Florence, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Microsystems represent an alternative but proficient approach of analysis outside the laboratory, and their use could help in reducing the impact of pre-analytical errors, in particular in challenging newborn samples. The study purpose is to compare the Horiba Microsemi CRP LC-767G system for rapid 3-part complete blood count (CBC) and C-reactive protein (CRP) determination with the laboratory reference systems (respectively Sysmex XN-9100™ and Roche Cobas® c702) in samples of adult patients and newborns hospitalized in the neonatal intensive care unit (NICU) samples. The comparison between the analyzers was performed through Passing-Bablok regression analysis and Bland-Altman plot. One hundred eighty-three blood samples were analyzed. The regression analysis results, performed in the newborn (n = 70) and in adult (n = 113) populations, showed a good agreement between the instruments. The evaluation of the Bland-Altman plots showed comparable values of bias < 10% for most of the parameters, but not for MPV, lymphocyte, and monocyte count.

conclusionThe comparison between the Microsemi CRP LC-767G system and the laboratory instrumentations demonstrated comparable results. The Microsemi CRP LC-767G system provides reliable analytical data and faster turnaround time, particularly useful in NICU. WHAT IS KNOWN: • Microsystems for point-of-care testing (POCT) represent an alternative but proficient approach of analysis outside the laboratory, in order to perform a rapid, safe, and exhaustive evaluation for critical patients' management, acting as a valid support for treatment in acute care. WHAT IS NEW: • The Microsemi CRP LC-767G system can represent an alternative but effective testing approach outside the laboratory, particularly in NICU, to reduce the impact of pre-analytical errors on newborn samples.

Indexed as

C-Reactive ProteinIntensive Care Units, NeonatalAdultBlood Cell CountFemaleHospitals, UniversityHumansInfant, NewbornMaleMiddle AgedReproducibility of ResultsC-Reactive ProteinComplete blood countC-reactive proteinHematology analyzerMicrosystemNewbornPerformance comparison

Identifiers

PMID39143348
PMCPMC11413159

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked