TEAM: Triangular-mEsh Adaptive and Multiscale proton spot generation method.
Article in Medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
backgroundProton therapy is preferred for its dose conformality to spare normal tissues and organs-at-risk (OAR) via Bragg peaks with negligible exit dose. However, proton dose conformality can be further optimized: (1) the spot placement is based on the structured (e.g., Cartesian) grid, which may not offer conformal shaping to complex tumor targets; (2) the spot sampling pattern is uniform, which may be insufficient at the tumor boundary to provide the sharp dose falloff, and at the same time may be redundant at the tumor interior to provide the uniform dose coverage, for example, due to multiple Coulomb scattering (MCS); and (3) the lateral spot penumbra increases with respect to the depth due to MCS, which blurs the lateral dose falloff. On the other hand, while (1) the deliverable spots are subject to the minimum-monitor-unit (MMU) constraint, and (2) the dose rate is proportional to the MMU threshold, the current spot sampling method is sensitive to the MMU threshold and can fail to provide satisfactory plan quality for a large MMU threshold (i.e., high-dose-rate delivery). PURPOSE: This work will develop a novel Triangular-mEsh-based Adaptive and Multiscale (TEAM) proton spot generation method to address these issues for optimizing proton dose conformality and plan delivery efficiency.
methodsCompared to the standard clinically-used spot placement method, three key elements of TEAM are as follows: (1) a triangular mesh instead of a structured grid: the triangular mesh is geometrically more conformal to complex target shapes and therefore more efficient and accurate for dose shaping inside and around the target; (2) adaptive sampling instead of uniform sampling: the adaptive sampling consists of relatively dense sampling at the tumor boundary to create the sharp dose falloff, which is more accurate, and coarse sampling at the tumor interior to uniformly cover the target, which is more efficient; and (3) depth-dependent sampling instead of depth-independent sampling: the depth-dependent sampling is used to compensate for MCS, that is, with increasingly dense sampling at the tumor boundary to improve dose shaping accuracy, and increasingly coarse sampling at the tumor interior to improve dose shaping efficiency, as the depth increases. In the TEAM method the spot locations are generated for each energy layer and layer-by-layer in the multiscale fashion; and then the spot weights are derived by solving the IMPT problem of dose-volume planning objectives, MMU constraints, and robustness optimization with respect to range and setup uncertainties.
resultsCompared to the standard clinically-used spot placement method UNIFORM, TEAM achieved (1) better plan quality using <60% number of spots of UNIFORM; (2) better robustness to the number of spots; (3) better robustness to a large MMU threshold. Furthermore, TEAM provided better plan quality with fewer spots than other adaptive methods (Cartesian-grid or triangular-mesh).
conclusionsA novel triangular-mesh-based proton spot placement method called TEAM is proposed, and it is demonstrated to improve plan quality, robustness to the number of spots, and robustness to the MMU threshold, compared to the clinically-used spot placement method and other adaptive methods.