ArticleJournal of arrhythmia2024
Incidence of pulmonary vein stenosis in two types of cryoballoon systems.
Article in Journal of arrhythmia, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Occluded pulmonary vein following a novel compliant cryoballoon ablation despite proximal seal technique.HeartRhythm case reports · 2025Article
- Comprehensive review of pulmonary vein stenosis post-atrial fibrillation ablation: diagnosis, management, and prognosis.Cardiovascular intervention and therapeutics · 2024Review
- Incidence of pulmonary vein stenosis in two types of cryoballoon systems.Journal of arrhythmia · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Currently, two types of cryoballoon (CB) systems are available for catheter ablation of atrial fibrillation (AF). Since the POLARx (Boston Scientific) is softer during freezing than the Arctic Front Advance Pro (AFA-Pro; Medtronic), it tends to go more deeply into the pulmonary vein (PV), risking PV stenosis. Methods: Ninety-one patients underwent initial CB ablation for paroxysmal AF (AFA-Pro 56; POLARx 35). Twenty-six from each group were extracted using propensity score matching. The PV cross-sectional area (PVA) was measured by tracing the area within the PV plane at 5-mm intervals from the PV ostium in a distal direction for 20 mm or to the bifurcation in each PV. The PVA was compared before and 3 months after ablation. Results: Time to balloon temperatures of -30 and - 40°C was significantly shorter and the nadir temperature was significantly lower with POLARx than with AFA-Pro. In the left inferior (LI) PV and right superior (RS) PV, the freezing balloon position was significantly deeper in POLARx than in AFA-pro. The freezing position in RSPV with mild to moderate narrowing was deeper than those without (10.2 ± 3.3 mm vs. 8.2 ± 1.8 mm, Conclusion: There was no significant difference in the incidence of PV stenosis between POLARx and AFA-Pro. However, if POLARx goes deep into the PVs, we will still have to be careful.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials