Evidence map›Paper›PMID 39138823›Full record

ArticleIntensive care medicine experimental2024

Venous return physiology applied to post-cardiac arrest haemodynamic management: a post hoc analysis of the NEUROPROTECT trial.

Anders Aneman, Markus Benedikt Skrifvars, Koen Ameloot

Abstract read
In one paragraph

Article in Intensive care medicine experimental, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Anders AnemanIntensive Care Unit, Liverpool Hospital, South Western Sydney Local Health District and South Western Sydney Clinical School, University of New South Wales, Sydney, Australia. anders.aneman@health.nsw.gov.au.ORCID http://orcid.org/0000-0003-2096-5304
Markus Benedikt SkrifvarsDepartment of Emergency Care and Services, Helsinki University Hospital and University of Helsinki, Helsinki, Finland.
Koen AmelootDepartment of Cardiology, Ziekenhuis Oost-Limburg, Genk, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe European Resuscitation Council 2021 guidelines for haemodynamic monitoring and management during post-resuscitation care from cardiac arrest call for an individualised approach to therapeutic interventions. Combining the cardiac function and venous return curves with the inclusion of the mean systemic filling pressure enables a physiological illustration of intravascular volume, vasoconstriction and inotropy. An analogue mean systemic filling pressure (Pmsa) may be calculated once cardiac output, mean arterial and central venous pressure are known. The NEUROPROTECT trial compared targeting a mean arterial pressure of 65 mmHg (standard) versus an early goal directed haemodynamic optimisation targeting 85 mmHg (high) in ICU for 36 h after cardiac arrest. The trial data were used in this study to calculate post hoc Pmsa and its expanded variables to comprehensively describe venous return physiology during post-cardiac arrest management. A general estimating equation model was used to analyse continuous variables split by standard and high mean arterial pressure groups.

resultsData from 52 patients in each group were analysed. The driving pressure for venous return, and thus cardiac output, was higher in the high MAP group (p < 0.001) along with a numerically increased estimated stressed intravascular volume (mean difference 0.27 [- 0.014-0.55] L, p = 0.06). The heart efficiency was comparable (p = 0.43) in both the standard and high MAP target groups, suggesting that inotropy was similar despite increased arterial load in the high MAP group (p = 0.01). The efficiency of fluid boluses to increase cardiac output was increased in the higher MAP compared to standard MAP group (mean difference 0.26 [0.08-0.43] fraction units, p = 0.01).

conclusionsCalculation of the analogue mean systemic filling pressure and expanded variables using haemodynamic data from the NEUROPROTECT trial demonstrated an increased venous return, and thus cardiac output, as well as increased volume responsiveness associated with targeting a higher MAP. Further studies of the analogue mean systemic filling pressure and its derived variables are warranted to individualise post-resuscitation care and evaluate any clinical benefit associated with this monitoring approach.

Indexed as

Cardiac arrestHaemodynamic managementMean systemic filling pressure

Identifiers

PMID39138823
PMCPMC11322455

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.